Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SELECT-ARC, INC. in 600 ENTERPRISE DRIVE, FORT LORAMIE, OH 45845 (NAICS 333992). OSHA activity number 339416406.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Select-Arc, INC. — free Get an email when a new federal OSHA severe-injury report for Select-Arc, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
SELECT-ARC, INC.
Site address
600 ENTERPRISE DRIVE
City
FORT LORAMIE
State
OH
ZIP
45845
Mailing
600 ENTERPRISE DRIVE, FORT LORAMIE, OH 45845
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333992
Employees
125
Ownership type
A

7 citations on file for this inspection.

1910.23 C01

Other-than-serious 1 instance 2 exposed
Issued
Feb 24, 2014
Abate by
Apr 16, 2014
Penalty
Initial $2,700 · Current $1,350 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:     a.)    Select-Arc, Inc. located at 600 Enterprise Dr. Fort Loramie, OH; On or about September 17, 2013, the employer did not assure the platform for the larger mixer in the flux room was equipped with a standard railing. Employees are required to use the platform to load the mixer and are exposed to a fall hazard of approximately 4 feet from the lack of a midrail.
Recent events (2)
  • — I (O) $1350
  • — Z (S) $2700

1910.147 C01

Serious Gravity 5 3 instances 16 exposed
Issued
Feb 24, 2014
Abate by
Oct 9, 2014
Penalty
Initial $4,500 · Current $2,250 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative;     a.)                Select-Arc, Inc. located at 600 Enterprise Dr. Fort Loramie, OH; On or about September 17, 2013, the employer did not assure an energy control program consisting of employee training, periodic inspections, and machine specific procedures, was established.   Employees were exposed to caught by hazards while using a vacuum hose to clean debris in between rotating blocks on draw benches #1-18, first draw and final draw.       b.)                Select-Arc, Inc. located at 600 Enterprise Dr. Fort Loramie, OH; On or about September 17, 2013, the employer did not assure an energy control program consisting of employee training, periodic inspections, and machine specific procedures, was established. Employees were exposed to amputation and crush hazards while changing plates on the GIMAX Spooler.      c.)                Select-Arc, Inc. located at 600 Enterprise Dr. Fort Loramie, OH; On or about September 17, 2013, the employer did not assure an energy control program consisting of employee training, periodic inspections, and machine specific procedures, was established. Employees were exposed to amputation and crush hazards while repairing wire breaks on the GIMAX Spooler.        per ISA: Abatement dates for machine specific procedures, an overall lock out program and associated training extended to 5/18/14 Abatement date for hazards that fall into an excepted lo/to status extended to 10/9/14
Recent events (2)
  • — I (S) $2250
  • — Z (S) $4500

1910.212 A01

Serious Gravity 10 4 instances 16 exposed
Issued
Feb 24, 2014
Abate by
Aug 7, 2015
Penalty
Initial $6,300 · Current $3,150 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a.)                 Select-Arc, Inc. located at 600 Enterprise Dr. Fort Loramie, OH; On or about September 17, 2013, the employer did not assure Draw Benches #1-18 were properly guarded. Employees were exposed to caught by and amputation hazards from the rotating blocks and tube mills while performing activities such as, but not limited to, refilling flux, mixing lube, and looking for dies that need to be changed.       b.)                Select-Arc, Inc. located at 600 Enterprise Dr. Fort Loramie, OH; On or about September 17, 2013, the employer did not assure the pay-off wheels for draw benches #1-18 were properly guarded. Employees were exposed to caught by hazards while working near the rotating pay off wheels weighing up to 5,000lbs.      c.)                Select-Arc, Inc. located at 600 Enterprise Dr. Fort Loramie, OH; On or about September 17, 2013, the employer did not assure the reel on draw bench #16 was properly guarded. Employees were exposed to caught by hazards while working near the reel.      d.)                Select-Arc, Inc. located at 600 Enterprise Dr. Fort Loramie, OH; On or about September 17, 2013, the employer did not assure the small mixer in the flux room was properly guarded. Employees were exposed to struck by hazards while rotating the mixer to loosen any remaining flux while inside the gate.
Recent events (2)
  • — I (S) $3150
  • — Z (S) $6300

1910.303 E

Other-than-serious 1 instance 5 exposed
Issued
Feb 24, 2014
Abate by
Mar 12, 2014
Penalty
Initial $2,700 · Current $1,350 Reduced
29 CFR 1910.303(e): Markings were not provided on electrical equipment giving voltage, current, wattage, and other ratings as necessary:    a.)    Select-Arc, Inc. located at 600 Enterprise Dr. Fort Loramie, OH; On or about September 17, 2013, the employer did not assure 480V electrical panels powering the draw benches were labeled with the voltage, exposing employees to electrical shock hazards.
Recent events (2)
  • — I (O) $1350
  • — Z (S) $2700

1910.333 A

Serious Gravity 10 1 instance 5 exposed
Issued
Feb 24, 2014
Abate by
Mar 26, 2014
Penalty
Initial $6,300 · Current $3,150 Reduced
29 CFR 1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized:     a.)    Select-Arc, Inc. located at 600 Enterprise Dr. Fort Loramie, OH; On or about September 17, 2013, the employer did not assure employees used electrical safety related work practices when accessing the 480V electrical panel of Draw Bench #13 to verify zero energy. Employees were exposed to electrical shock and arc flash hazards from the 480V equipment in that proper personal protective equipment was not worn.
Recent events (2)
  • — I (S) $3150
  • — Z (S) $6300

1910.332 B01

Serious Gravity 10 1 instance 5 exposed
Issued
Feb 24, 2014
Abate by
Mar 26, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:   a.)    Select-Arc, Inc. located at 600 Enterprise Dr. Fort Loramie, OH; On or about September 17, 2013, the employer did not assure employees were provided with training on protective equipment for the face, hands, and body to protect against electrical hazards while working on or near energized conductors. Employees are required to verify zero energy and perform programming activities near potentially live 480V circuits, exposing them to electrical shock and arc flash hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.335 A01 I

Serious Gravity 10 5 instances 5 exposed
Issued
Feb 24, 2014
Abate by
Mar 26, 2014
Penalty
Initial $6,300 · Current $3,150 Reduced
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed:    a.) Select-Arc, Inc. located at 600 Enterprise Dr. Fort Loramie, OH; On or about September 17, 2013, the employer did not assure employees wore personal protective equipment, including but not limited to, insulated gloves with protective gloves, arc rated clothing, face shield and nonconductive hard hat while verifying zero energy in order to remove one fuse in a 480V electrical cabinet for Draw Bench #13, exposing employees to electrical shock and arc flash hazards.
Recent events (2)
  • — I (S) $3150
  • — Z (S) $6300

View Select-Arc, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339416406.