MOUNT HOPE, OH ·
OSHA Inspection: OVERHEAD DOOR CORPORATION-WAYNE DALTON
Fatality or catastrophe inspection · Safety discipline
At a glance
On , OSHA opened a fatality or catastrophe safety inspection of OVERHEAD DOOR CORPORATION-WAYNE DALTON in 1 DOOR DRIVE, MOUNT HOPE, OH 44660 (NAICS 332321). OSHA activity number 339430803.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OVERHEAD DOOR CORPORATION-WAYNE DALTON
- Site address
- 1 DOOR DRIVE
- City
- MOUNT HOPE
- State
- OH
- ZIP
- 44660
- Mailing
- 1 DOOR DRIVE, MOUNT HOPE, OH 44660
What kind of inspection was it?
- Inspection type
- Fatality or catastrophe (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332321
- Employees
- 575
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Feb 6, 2014
- Abate by
- Mar 14, 2014
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following: 29 CFR 1910.147(c)(4)(ii)(B): Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy; a. Located on the W-24 Spring Winder at Overhead Door in Mount Hope, Ohio, there were lockout/tag out procedures that did not include specific procedural steps on protecting the employees from stored pneumatic energy, how to verify de-energized sources, and how to properly shut down the equipment, thereby exposing the employees to the hazards associated with working on or around the W-24 Spring Winder and/or uncoiler payoff.
Recent events (2)
- · I (S) $7000
- · Z (S) $7000
1910.212 A01
- Issued
- Feb 6, 2014
- Abate by
- Mar 5, 2014
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc. a. Located on the W-24 Spring Winder at Overhead Door in Mount Hope, Ohio, employees cut metal wire under tension with hydraulic cutters between the measurement box and the cube shaped wire cage which enclosed the uncoiler, thereby exposing the employees to potential contact with moving metal wire. b. Located on the W-24 Spring Winder at Overhead Door - Wayne Dalton in Mount Hope, Ohio, there were employees that were required to make adjustments by hand to a spring run out tray with a wing nut that was located inches from the drive wheels of the Spring Winder, thereby exposing the employees to the ingoing nip points of the drive wheels.
Recent events (2)
- · I (S) $7000
- · Z (S) $7000
1910.212 A02
- Issued
- Feb 6, 2014
- Abate by
- Mar 5, 2014
- Penalty
- Initial $5,500 · Current $5,500
General-duty citation text
29 CFR 1910.212(a)(2): General requirements for machine guards. Guards shall be affixed to the machine where possible and secured elsewhere if for any reason attachment to the machine is not possible. The guard shall be such that it does not offer an accident hazard in itself. a. Located on the W-24 Spring Winder at Overhead Door - Wayne Dalton in Mount Hope, Ohio, there were employees that were required to operate W-24 spring winder without a barrier guard that was affixed to its equipment. The guard could be removed by hand by an employee, thereby exposing the employees to the ingoing nip points of the spring winders drive wheels. b. Located on the W-24 Spring Winder at Overhead Door in Mount Hope, Ohio, there were employees that were required to operate W-24 Spring Winder's wire counter without a barrier guard that was affixed to its equipment. The guard was on hinges and could be removed by hand by an employee, thereby exposing the employees to the ingoing nip points of the v-guides and rollers of the wire counter.
Recent events (2)
- · I (S) $5500
- · Z (S) $5500
More inspections at Overhead Door Corporation-Wayne Dalton
View Overhead Door Corporation-Wayne Dalton's full OSHA safety record →
More inspections in this industry (NAICS 332321)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339430803.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.