COLUMBUS, OH —
OSHA Inspection: ALDERETE CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ALDERETE CONSTRUCTION in 1231 GABRIELLE ELAINE DR., COLUMBUS, OH 43228 (NAICS 238130). OSHA activity number 339454464.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALDERETE CONSTRUCTION
- Site address
- 1231 GABRIELLE ELAINE DR.
- City
- COLUMBUS
- State
- OH
- ZIP
- 43228
- Mailing
- 378 JAMESTOWN CT., COLUMBUS, OH 43228
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 20
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.178 A04
- Issued
- Nov 19, 2013
- Abate by
- Jan 24, 2014
- Penalty
- Initial $1,600 · Current $560 Reduced
General-duty citation text
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation shall not be performed by the customer or user without manufacturers prior written approval. Capacity, operation, and maintenance instruction plates, tags, or decals shall be changed accordingly. a. At Building 5 where employees were using a Sky Trak rough terrain forklift to lift trusses into place without written permission from the manufacturer modiyfing the the powered industrial truck exposes the employees to a struck-by hazard.
Recent events (2)
- — I (S) $560
- — Z (S) $1600
1926.404 F06
- Issued
- Nov 19, 2013
- Penalty
- Initial $1,200 · Current $420 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous. a. On Building 5 where an extension cord was used to provide power to portable tools, the ground prong was missing thereby exposing employees to a contact hazard.
Recent events (2)
- — I (S) $420
- — Z (S) $1200
1926.405 A02 II I
- Issued
- Nov 19, 2013
- Penalty
- Initial $1,200 · Current $420 Reduced
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables shall be protected from damage. Sharp corners and projections shall be avoided. Flexible cords and cables may pass through doorways or other pinch points, if protection is provided to avoid damage. a. At the front of Building 10, there was a extension cord which ran across the dirt road and was exposed to damage from vehicle traffic to provide power to the framers on the roof thereby exposing employees to a contact hazard.
Recent events (2)
- — I (S) $420
- — Z (S) $1200
1926.501 B13
- Issued
- Nov 19, 2013
- Abate by
- Nov 29, 2013
- Penalty
- Initial $2,800 · Current $1,540 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems. a. On the roof of building 5 where the employees were framing the roof deck, employees of Alderete Construction were not wearing fall protection thereby exposing employees to a fall hazard.
Recent events (2)
- — I (S) $1540
- — Z (S) $2800
1926.602 C01 VIII A
- Issued
- Nov 19, 2013
- Abate by
- Nov 29, 2013
- Penalty
- Initial $1,600 · Current $0 Reduced
General-duty citation text
29 CFR 1926.602(c)(1)(viii)(A): Use of a safety platform firmly secured to the lifting carriage and/or forks. a. On the site beside building 5, the platform on the front of the rough terrain forklift was not secured to the forks to prevent displacement when lifting trusses thereby exposing employees to a struck-by hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $1600
1926.1052 C01
- Issued
- Nov 19, 2013
- Abate by
- Nov 29, 2013
- Penalty
- Initial $1,200 · Current $420 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with: 29 CFR 1926.1052(c)(1)(i): At least one handrail; a. At Building 5 where employees used the stairways to gain access to the second floor and then onto the roof to perform framing, there were no handrails thereby exposing employees to a trip/fall hazard.
Recent events (2)
- — I (S) $420
- — Z (S) $1200
More inspections at Alderete Construction
View Alderete Construction's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339454464.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.