Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KIMBERLY A. RIOS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of KIMBERLY A. RIOS in 534 E SOUTH RIVER STREET, APPLETON, WI 54915 (NAICS 238160). OSHA activity number 339481418.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kimberly a. Rios — free Get an email when a new federal OSHA severe-injury report for Kimberly a. Rios is published. One employer, no account, unsubscribe in one click.
Establishment
KIMBERLY A. RIOS
Site address
534 E SOUTH RIVER STREET
City
APPLETON
State
WI
ZIP
54915
Mailing
831 W. PACKARD ST, APPLETON, WI 54914
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

9 citations on file for this inspection.

1926.151 A02

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 27, 2013
Abate by
Jan 21, 2014
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.151(a)(2): Internal combustion engine powered equipment shall be so located that the exhausts are well away from combustible materials. When the exhausts are piped to outside the building under construction, a clearance of at least 6 inches shall be maintained between such piping and combustible material:  a)  On and or about 11-05-13, employees were utilizing a Rolair compressor while positioned in the back of a work pickup truck with an open fuel container positioned against one side of the compressor.  Abatement Certification Required
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2000

1926.152 F01

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 27, 2013
Abate by
Jan 21, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.152(f)(1): Flammable liquids were not kept in closed containers when not actually in use:   a)  On and or about 11-5-13, employees were utilizing a 5 gallon fuel container to power a Rolair compressor; the fuel container was left open when stored against the side of the running compressor in the back of a work pickup truck.  Abatement Certification Required
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.152 F03

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 27, 2013
Abate by
Jan 21, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.152(f)(3): Flammable liquids were used where there were open flames or other sources of ignition within 50 feet of the operation:Note:  Certain conditions warrant that flammable liquids be used farther than 50 feet from open flames or other sources of ignition:  a)  On and or about 11-5-13, employees were utilizing a Rolair compressor positioned in the back of a work pickup truck with an open five (5) gallon fuel container positioned against the side of the running compressor.  Abatement Certification Required
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.151 C06

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 27, 2013
Abate by
Jan 21, 2014
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.151(c)(6): Portable fire extinguishing equipment, suitable for the fire hazard(s) involved, was not provided at convenient, conspicuously accessible locations in the yard area:  a)  On and or about 11-5-13, employees who were using fuel to power a Rolair compressor did not have a fire extinguisher readily assessable; the fire extinguisher was said to be buried under materials and equipment in the work pickup truck.  Abatement Certification Required
Recent events (2)
  • — I (S) $1600
  • — Z (S) $1600

1926.501 B13

Willful Gravity 10 3 instances 4 exposed
Issued
Nov 27, 2013
Abate by
Jan 21, 2014
Penalty
Initial $14,000 · Current $6,000 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):       a)      On and or about 11-5-13, employees were working on a 5:12 pitch, third story residential roof with an eave edge greater than twenty-five (25) feet above compacted surface without utilizing fall protection equipment.    b)      On and or about 11-05-13, employees were accessing a residential third story roof by walking on a 5:12 pitch, second story roof with an eave edge greater than twenty (20) feet above compacted surface without utilizing fall protection equipment.    c)      On and or about 11-05-13, employees who were using an extension ladder between a first story roof surface and second story roof surface were walking on a low slope porch roof with an eave edge thirteen (13) feet above compacted surface without utilizing fall protection equipment.    Abatement Certification and Abatement Documentation Required
Recent events (2)
  • — I (W) $6000
  • — Z (W) $14000

1926.102 A01

Repeat Gravity 5 1 instance 2 exposed
Issued
Nov 27, 2013
Abate by
Jan 21, 2014
Penalty
Initial $4,000 · Current $2,000 Reduced
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:    a)  On and or about 11-5-13, employees who were working on a roof were operating pneumatic nail guns without wearing eye protection.      Bacilio Rios Roofing was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 1926.102(a)(1), which was contained in OSHA Inspection Number 107030, Citation Number 01, item number 001, and was affirmed as a Final Order on 02-10-12, with respect to a workplace located at 1619 Greenwood, Greenville, WI  54942.    Abatement Certification Required
Recent events (2)
  • — I (R) $2000
  • — Z (R) $4000

1926.503 A02 VIII

Repeat Gravity 5 1 instance 4 exposed
Issued
Nov 27, 2013
Abate by
Jan 21, 2014
Penalty
Initial $4,000 · Current $1,000 Reduced
29 CFR 1926.503(a)(2)(viii): The employer did not assure that each employee had been trained by a competent person qualified in the standards contained in subpart M:    a)  On and or about 11-5-13, employer did not assure that each employee had been trained, as necessary, by a competent person qualified in the requirements of Subpart M; employees who were performing roofing repair work did not utilize fall protection equipment when walking and working on three roof levels each greater than ten (10) feet above compacted surfaces.    Bacilio Rios Roofing was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA Inspection Number 312552151 (86798), Citation Number 01, item number 1a, and was affirmed as a Final Order on 10-13-09, with respect to a workplace located at 7849 Edgewater Ct.; Sherwood, WI  54169.    Abatement Certification and Abatement Documentation Required
Recent events (2)
  • — I (R) $1000
  • — Z (R) $4000

1926.1053 B01

Repeat Gravity 5 1 instance 4 exposed
Issued
Nov 27, 2013
Abate by
Jan 21, 2014
Penalty
Initial $3,200 · Current $2,000 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:     a)      On and or about 11-5-13, employees were utilizing a twenty (20) ft. Louisville extension ladder as the roof access point between a first story porch roof surface and a second story roof surface without the side rails extending at least three (3) feet above the upper surface; porch roof low slope with eave edge thirteen (13) feet above compacted surface; second story roof access point eight (8) feet above the porch roof surface.     Bacilio Rios Roofing was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 1926.1053(b)((1), which was contained in OSHA Inspection Number 312552151 (86798), Citation Number 01, item number 2, and was affirmed as a Final Order on 10-13-09, with respect to a workplace located at 7849 Edgewater Ct.; Sherwood, WI  54169.     Abatement Certification Required
Recent events (2)
  • — I (R) $2000
  • — Z (R) $3200

1926.1060 A01 V

Other-than-serious 1 instance 4 exposed
Issued
Nov 27, 2013
Abate by
Jan 21, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.1060(a)(1)(v): The employer did not ensure that each employee using ladders and/or stairways had been trained by a competent person in the standards contained in Subpart X:   a)      On and or about 11-5-13, employer did not assure that each employee who was utilizing extension ladders to access roof work surfaces had been trained, as necessary, by a competent person qualified in the requirements of Subpart X.  Abatement Certification Required
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Kimberly a. Rios's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339481418.