POPLAR BLUFF, MO —
OSHA Inspection: REVERE PLASTICS SYSTEMS, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of REVERE PLASTICS SYSTEMS, LLC in 1452 ROWE PARKWAY, POPLAR BLUFF, MO 63901 (NAICS 326199). OSHA activity number 339483000.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- REVERE PLASTICS SYSTEMS, LLC
- Site address
- 1452 ROWE PARKWAY
- City
- POPLAR BLUFF
- State
- MO
- ZIP
- 63901
- Mailing
- 1452 ROWE PARKWAY, POPLAR BLUFF, MO 63901
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 165
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.212 A01
- Issued
- Nov 19, 2013
- Abate by
- Dec 7, 2013
- Penalty
- Initial $3,300 · Current $2,310 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: At the time of the inspection, the Journeyman vertical bandsaw was operated with the unused portion of the blade unguardes exposing employees to the rotating blade. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations.
Recent events (2)
- — I (S) $2310
- — Z (S) $3300
1910.253 B04 I
- Issued
- Nov 19, 2013
- Abate by
- Dec 7, 2013
- Penalty
- Initial $3,300 · Current $2,310 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire; At the time of the inspection, oxygen cylinders were stored with acetylene cylinders in the shop area adjacent the lathe. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations.
Recent events (2)
- — I (S) $2310
- — Z (S) $3300
1910.305 B01
- Issued
- Nov 19, 2013
- Abate by
- Dec 7, 2013
- Penalty
- Initial $3,300 · Current $2,310 Reduced
General-duty citation text
29 CFR 1910.305(b)(1): Unused openings in boxes, cabinets, or fittings were not effectively closed: At the time of the inspection multiple cabinets and boxes were documented with unused openings uncovered exposing employees in the area to live electrical hazards. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations.
Recent events (2)
- — I (S) $2310
- — Z (S) $3300
1910.169 B03 IV
- Issued
- Nov 19, 2013
- Abate by
- Dec 7, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.169(b)(3)(iv): Safety valve(s) on compressed air receiver(s) were not tested at frequently regular intervals to determine if they were in good operating condition: At the time of the inspection, the employer had no record of any testing of the safety valve on the main air receiver. The last State inspection was done in 1999.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Revere Plastics Systems, LLC
View Revere Plastics Systems, LLC's full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339483000.