TULSA, OK —
OSHA Inspection: BADGER METER, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BADGER METER, INC. in 6116 E. 15TH ST., TULSA, OK 74112 (NAICS 332911). OSHA activity number 339497794.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BADGER METER, INC.
- Site address
- 6116 E. 15TH ST.
- City
- TULSA
- State
- OK
- ZIP
- 74112
- Mailing
- 6116 E. 15TH ST., TULSA, OK 74112
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332911
- Employees
- 69
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.106 E06 II
- Issued
- Jan 30, 2014
- Abate by
- Feb 7, 2014
- Penalty
- Initial $2,550 · Current $1,530 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Class I flammable liquid(s) were dispensed into containers, vehicles, and equipment without electrically interconnecting the nozzle and the container, vehicles, or equipment: On or about November 20, 2013, and at times prior thereto, in the paint areas Anchor J 5 lacquer thinner having flashpoint of less than -1 degrees F was dispensed into a smaller container without being effectively grounded and bonded to electrically interconnect the containers to prevent static discharge during dispensing operation exposing employees to a fire hazard.
Recent events (2)
- — I (S) $1530
- — Z (S) $2550
1910.107 B05 IV
- Issued
- Jan 30, 2014
- Abate by
- Mar 17, 2014
- Penalty
- Initial $2,550 · Current $1,530 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers: On or about November 20, 2013, and at times prior thereto, employees were required to perform spray painting operation in the spray booth which was not protected with approved automatic sprinklers. Employees were exposed to fire hazards.
Recent events (2)
- — I (S) $1530
- — Z (S) $2550
1910.107 G05
- Issued
- Jan 30, 2014
- Abate by
- Feb 24, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(g)(5): The use of solvents for cleaning operations was not restricted to those having flashpoints not less than 100 degrees F or the solvents having flashpoints less than those normally used in the spray operation: On or about November 20, 2013, and at times prior thereto, in the spray paint areas employees were allowed to use Anchor J 5 lacquer thinner having flashpoint of less than -1 degrees F as a solvent for cleaning operations. This exposes employees to fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Jan 30, 2014
- Abate by
- Feb 24, 2014
- Penalty
- Initial $3,400 · Current $2,040 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts: On or about November 20, 2013, and at times prior thereto, in the casting line and machine shop areas employees were observed operating CNC machines that were either not provided with an interlock device or the interlock device was not working. Employees were exposed to caught in and struck by hazards.
Recent events (2)
- — I (S) $2040
- — Z (S) $3400
1910.303 B02
- Issued
- Jan 30, 2014
- Abate by
- Feb 3, 2014
- Penalty
- Initial $2,550 · Current $1,530 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On or about November 20, 2013, and at times prior thereto, in the DIC break room areas a relocatable power tap (RPT) was observed being used not in accordance with the listed instructions where it was used to provide power to large current consumption equipment. Employees were exposed to fire hazards.
Recent events (2)
- — I (S) $1530
- — Z (S) $2550
1910.304 B02
- Issued
- Jan 30, 2014
- Abate by
- Feb 3, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(b)(2): Outlet devices had an ampere rating less than the load being served: On or about November 20, 2013, or at times prior thereto, in the DCI break room areas electrical equipment were observed plugged into the same outlet device which had a current rating less than the load being served. This exposed employees to fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 I01 II C
- Issued
- Jan 30, 2014
- Abate by
- Mar 17, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(i)(1)(ii)(C): The employer did not ensure that the carbon monoxide (CO) content of the compressed breathing air 10 ppm or less: On or about November 20, 2013, or at times prior thereto, in the paint areas employees were required to use supplied air respirator which did not have a carbon monoxide (CO) monitor provided to monitor the CO content. Employees were exposed to respiratory hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.147 C07 I
- Issued
- Jan 30, 2014
- Abate by
- Feb 24, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: On or about November 21, 2013 and at times prior thereto, at the establishment an employee was required to perform maintenance and repairing some equipment at the facility but did not have Lock-out/Tag-out training provided. The employee was exposed to hazards from the unexpected release of energy.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Badger Meter, INC.
View Badger Meter, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332911)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339497794.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.