WICKLIFFE, OH ·
OSHA Inspection: PCC AIRFOILS LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PCC AIRFOILS LLC in 29501 CLAYTON BLVD, WICKLIFFE, OH 44092 (NAICS 336412). OSHA activity number 339503153.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PCC AIRFOILS LLC
- Site address
- 29501 CLAYTON BLVD
- City
- WICKLIFFE
- State
- OH
- ZIP
- 44092
- Mailing
- 29501 CLAYTON BLVD, WICKLIFFE, OH 44092
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336412
- Employees
- 380
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.23 C01
- Issued
- Mar 17, 2014
- Penalty
- Initial $4,000 · Current $2,800 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floor(s) or platform(s) 4 feet (1.22 m) or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides: Employee(s), who access the tops of equipment when completing maintenance activities such as, replacing the graphite baffle of the furnace(s) located in the Foundry department, were exposed to a fall hazard.
Recent events (2)
- · I (S) $2800
- · Z (S) $4000
1910.147 C05 II
- Issued
- Mar 17, 2014
- Abate by
- Apr 9, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(5)(ii): Lockout devices and tagout devices were not singularly identified: Employees tasked with locking out machinery during maintenance activities were not provided with individual lockout/tagout devices.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at PCC Airfoils LLC
View PCC Airfoils LLC's full OSHA safety record →
More inspections in this industry (NAICS 336412)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339503153.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.