OWENS CROSS ROADS, AL —
OSHA Inspection: ULTRATEC SPECIAL EFFECTS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ULTRATEC SPECIAL EFFECTS, INC. in 148 MOON DRIVE, OWENS CROSS ROADS, AL 35763 (NAICS 325998). OSHA activity number 339513392.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ULTRATEC SPECIAL EFFECTS, INC.
- Site address
- 148 MOON DRIVE
- City
- OWENS CROSS ROADS
- State
- AL
- ZIP
- 35763
- Mailing
- 148 MOON DRIVE, OWENS CROSS ROADS, AL 35763
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325998
- Employees
- 46
- Ownership type
- A
Citations
7 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 30, 2014
- Abate by
- May 6, 2014
- Penalty
- Initial $5,390 · Current $3,775 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to explosion and fire hazards: (a) On or about 11/21/13 - in the C3 Process Building, the employer allowed research and development work to be conducted in the same process building where manufacturing work was being conducted instead of in a pyrotechnic laboratory. The employer's maximum quantity limitations allowed 20-lbs of pyrotechnic composition in the C3 Process building.
Recent events (2)
- — I (S) $3775
- — Z (S) $5390
1910.36 H03
- Issued
- Apr 30, 2014
- Abate by
- May 27, 2014
- Penalty
- Initial $2,888 · Current $1,445 Reduced
General-duty citation text
29 CFR 1910.36(h)(3): Outdoor exit route(s) were not reasonably straight and did not have smooth, solid, substantially level walkways: (a) On or about 12/11/13 - at C3 Process building, the southern exit route at the east end of the building has a downhill sloped and is covered with pine needles.
Recent events (2)
- — I (S) $1445
- — Z (S) $2888
1910.119 D03 II
- Issued
- Apr 30, 2014
- Abate by
- Jun 26, 2014
- Penalty
- Initial $2,888 · Current $1,445 Reduced
General-duty citation text
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices: (a) On or about 12/11/13 - at the C2 Processing building, the fiber drum waste receptacle used in a location classified as Class II, Division 1 and where employees were assembling pyrotechnic articles was not approved and equipped with a cover as per NFPA 495-2006, section 5.2.5. (b) On or about 12/11/13 - at C12 Processing Building, the plastic waste receptacle used in a location classified as Class II, Division 1 and where employees were assembling pyrotechnic articles was not approved and equipped with a cover as per NFPA 495-2006, section 5.2.5.
Recent events (2)
- — I (S) $1445
- — Z (S) $2888
1910.212 A01
- Issued
- Apr 30, 2014
- Abate by
- May 8, 2014
- Penalty
- Initial $2,310 · Current $1,385 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) On or about 12/11/13 - at C2 Processing Building, the rotating chuck and swarf were not guarded on the Craftsman 10" drill press. (b) On or about 12/11/13 - at C10 Temporary Prep Building, the rotating chuck and swarf were not guarded on the Dayton 10" drill press.
Recent events (2)
- — I (S) $1385
- — Z (S) $2310
1910.303 B07 IV
- Issued
- Apr 30, 2014
- Abate by
- May 8, 2014
- Penalty
- Initial $5,390 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(iv): There were damaged parts that adversely affected safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating: (a) On or about 12/11/13 - at A4 Mixing Building, the cord bushing for the Star Mine Mixer used in a hazardous location classified as Class1 Division1 was pulled out from the Class I electrical plug allowing vapors to enter the plug housing which was plugged into a Class I receptacle.
Recent events (2)
- — I (S) $4000
- — Z (S) $5390
1910.307 C02 I
- Issued
- Apr 30, 2014
- Abate by
- Jun 26, 2014
- Penalty
- Initial $7,700 · Current $5,390 Reduced
General-duty citation text
29 CFR 1910.307(c)(2)(i): Equipment in hazardous (classified) location(s) was not approved for the ignitable or combustible properties of the specific gas, vapor, dust, or fiber that was or could be present: (a) On or about 12/11/13 - at Processing Building C2, the Auto Labe Semi-Automatic Round Product Labeler and Manual Label Dispenser did not have marking to show its suitability for use in the building C2 that was classified as Class II, Division 1. (b) On or about 12/11/13 - at Processing Building C2, the ITW Dynatec Hand Applicator did not have markings to show its suitability for use in the building C2 that was classified as Class II, Division 1. (c) On or about 12/11/13 - at Processing Building C12 , the ITW Dynatec Hand Applicator did not have markings to show its suitability for use in the building C12 that was classified as Class II, Division 1. Ultratec Speical Effects, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 313086266, citation number 01, item number 017 and was affirmed as a final order on 10/26/09, with respect to a workplace located at 148 Moon Drive, Owens Cross Roads, Al 35763.
Recent events (2)
- — I (R) $5390
- — Z (R) $7700
1910.119 F01
- Issued
- Apr 30, 2014
- Abate by
- Jun 26, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(f)(1): The employer did not develop and implement written operating procedures that provide clear instructions for safely conducting activities involved in each covered process consistent with the process safety information: (a) On or about 12/11/13 - at C2 Processing building, portable electrical and electronic equipment such as but not limited to the 2-way radios were allowed in the processing area and were not included as being permissible to the area in the written standard operating procedures such as but not limited to Profetti Airburst Assembly and Build/Assemble PP Preloaded AB Charges. (b) On or about 12/11/13 - at A4 Mixing building, portable electrical and electronic equipment such as but not limited to the 2-way radios were allowed in the processing area and were not included as being permissible to the area in the written standard operating procedures such as but not limited to Preparing Ammonium Perchlorate Based Starmines and Preparing Nitrocellulose Based Starmines.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Ultratec Special Effects, INC.
View Ultratec Special Effects, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325998)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339513392.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.