Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THERM-O-LINK OF TEXAS INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of THERM-O-LINK OF TEXAS INC. in 1295 HENRY BRENNAN, EL PASO, TX 79936 (NAICS 331422). OSHA activity number 339517385.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Therm-O-Link of Texas INC. — free Get an email when a new federal OSHA severe-injury report for Therm-O-Link of Texas INC. is published. One employer, no account, unsubscribe in one click.
Site address
1295 HENRY BRENNAN
City
EL PASO
State
TX
ZIP
79936
Mailing
1295 HENRY BRENNAN, EL PASO, TX 79936
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331422
Employees
240
Ownership type
A

4 citations on file for this inspection.

1910.23 A05

Serious Gravity 5 1 instance 5 exposed
Issued
May 19, 2014
Abate by
May 23, 2014
Penalty
Initial $3,600 · Current $1,800 Reduced
29 CFR 1910.23(a)(5): Infrequently used pit or trap door floor opening(s) with the cover(s) removed were not constantly attended by someone or protected on all exposed sides by removable standard railings.    On December 11, 2013 and times prior to, a pit door located in the back of the facility near the steam pump, was open and was not attendend by anyone. This condition exposed employees to trip and fall hazards.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $3600

1910.219 D01

Serious Gravity 5 2 instances 5 exposed
Issued
May 19, 2014
Abate by
Jun 13, 2014
Penalty
Initial $3,600 · Current $1,800 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements.    On December 11, 2013 and times prior to, employer did not use proper guading on the VL-3 Machine. This condion exposed employee to cuts, lacerations, and amputaion hazards.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $3600

1910.305 B01 II

Serious Gravity 5 2 instances 20 exposed
Issued
May 19, 2014
Abate by
Jun 13, 2014
Penalty
Initial $5,400 · Current $2,700 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed.    On December 11, 2013, and times prior to, employees were working near electrical boxes located in the main entrance hallway, vinyl 2 machine, and in front of the steam generators, were not effectively closed. This condition exposed employees to electrical hazards.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $5400

1910.305 G02 III

Serious Gravity 5 1 instance 3 exposed
Issued
May 19, 2014
Abate by
Jun 13, 2014
Penalty
Initial $5,400 · Current $2,700 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws.    On December 11, 2013, and times prior to, employees were exposed to electrical hazards due to misisng strain relief or similar device.  This condition exposed employee to electrical hazards.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $5400

View Therm-O-Link of Texas INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339517385.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.