Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NATIONAL MANAGEMENT RESOURCES CORPORATION

Unprogrammed Other inspection · Health discipline

On , OSHA opened an unprogrammed Other health inspection of NATIONAL MANAGEMENT RESOURCES CORPORATION in 1311 S 9TH STREET, OMAHA, NE 68108 (NAICS 561720). OSHA activity number 339521817.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch National Management Resources Corporation — free Get an email when a new federal OSHA severe-injury report for National Management Resources Corporation is published. One employer, no account, unsubscribe in one click.
Site address
1311 S 9TH STREET
City
OMAHA
State
NE
ZIP
68108
Mailing
113 CORPORATE PARKE EAST DRIVE PO BOX 1224, LAGRANGE, GA 30241
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561720
Employees
15
Ownership type
A

9 citations on file for this inspection.

1910.134 E01

Serious Gravity 5 2 instances 6 exposed
Issued
Apr 21, 2014
Abate by
Mar 2, 2015
Penalty
Initial $5,100 · Current $3,570 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:    a)    Grounds Department - Grace University: Employees are required to wear tight-fitting elastomeric half-mask respirators and the employer had not provided medical evaluations prior to requiring the employees to wear respiratory protection in the workplace.      b)    Housekeeping Department - Grace University: Employees are required to wear filtering facepiece N95 respirators and the employer had not provided medical evaluations prior to requiring the employees to wear respiratory protection in the workplace.      Abatement certification is required for this violation.  The abatement certification sheet is enclosed with the citations.
Recent events (3)
  • — F (S) $3570
  • — C (S) $5100
  • — Z (S) $5100

1910.134 F01

Serious Gravity 5 2 instances 6 exposed
Issued
Apr 21, 2014
Abate by
Mar 2, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(1): The employer did not ensure that an employee using a tight-fitting facepiece respirator is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter:     a)         Grounds Department  Grace University: Employees are required to wear tight-fitting elastomeric half-mask respirators and the employer had not provided fit-testing prior to requiring the employees to wear respiratory protection in the workplace.       b)         Housekeeping Department  Grace University: Employees are required to wear filtering facepiece N95 respirators and the employer had not provided fit-testing prior to requiring the employees to wear respiratory protection in the workplace.      Abatement certification is required for this violation.  The abatement certification sheet is enclosed with the citations.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.134 K03

Serious Gravity 5 2 instances 6 exposed
Issued
Apr 21, 2014
Abate by
Mar 2, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace:      a)    Grounds Department - Grace University: Employees are required to wear tight-fitting elastomeric half-mask respirators and the employer had not provided respiratory protection training prior to requiring the employees to wear respiratory protection in the workplace.      b)     Housekeeping Department - Grace University: Employees are required to wear filtering facepiece N95 respirators and the employer had not provided respiratory protection training prior to requiring the employees to wear respiratory protection in the workplace.      Abatement certification is required for this violation.  The abatement certification sheet is enclosed with the citations.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 21, 2014
Abate by
Mar 2, 2015
Penalty
Initial $3,400 · Current $3,570
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section:      Jobsite  Basement: The employer did not develop, document and utilize specific lockout procedures for doing service or maintenance work on Boiler unit to ensure the employees are properly locking out all energy sources to the motor.      Abatement certification is required for this violation.  The abatement certification sheet is enclosed with the citations.
Recent events (3)
  • — F (S) $3570
  • — C (S) $3400
  • — Z (S) $3400

1910.147 C05 I

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 21, 2014
Abate by
Mar 2, 2015
Penalty
Initial $3,400 · Current $0 Reduced
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing, or blocking of machines or equipment from energy sources:      Maintenance Department  Grace University: no locks, tags or other hardware were provided for employees performing maintenance and repair of machines and equipment including, but not limited to the Boiler units.      Abatement certification is required for this violation.  The abatement certification sheet is enclosed with the citations.
Recent events (3)
  • — F (S) $0
  • — C (S) $3400
  • — Z (S) $3400

1910.147 D04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 21, 2014
Abate by
Mar 2, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:      Maintenance Department Grace University: no locks, tags or other hardware were affixed by authorized employees performing maintenance and repair of machines and equipment including, but not limited to the Boiler units.      Abatement certification is required for this violation.  The abatement certification sheet is enclosed with the citations.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.1200 G01

Other-than-serious 1 instance 4 exposed
Issued
Apr 21, 2014
Abate by
Mar 2, 2015
Penalty
Initial $0 · Current $500
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use:     Facilities Department  Grace University: A material safety data sheet for Acridinium Trigger Solution II was not maintained at the jobsite.      Abatement certification is required for this violation.  The abatement certification sheet is enclosed with the citations.
Recent events (3)
  • — F (O) $500
  • — C (S) $0
  • — Z (S) $0

1910.1200 E01 I

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Apr 21, 2014
Abate by
Jun 6, 2014
Penalty
Initial $3,400 · Current $0 Reduced
29 CFR 1910.1200(e)(1)(i): The written hazard communication program did not include a list of the hazardous chemicals known to be present using an identity that is referenced on the appropriate material safety data sheet:     Facilities Department  Grace University: The employer did not develop a list of the hazardous chemicals, including Acridinium Trigger Solution II, known to be present that use an identity that is referenced on the appropriate material safety data sheet.    Abatement certification is required for this violation.  The abatement certification sheet is enclosed with the citations.
Recent events (3)
  • — F (S) $0
  • — C (S) $3400
  • — Z (S) $3400

1910.1200 H02 III

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Apr 21, 2014
Abate by
Jun 6, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(2)(iii): The employer did not provide information to the employees as to the location and availability of the written hazard communication program, including the list(s) of hazardous chemicals required by this section:    Facilities Department  Grace University: Employees did not receive training that included the list of hazardous chemicals in the workplace.    Abatement certification is required for this violation.  The abatement certification sheet is enclosed with the citations.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

View National Management Resources Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339521817.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.