Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: BOULDER ROOFING INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BOULDER ROOFING INC. in 2355 CRAGMOOR RD., BOULDER, CO 80305 (NAICS 238160). OSHA activity number 339544967.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Boulder Roofing INC. for free Get an email when a new federal OSHA severe-injury report for Boulder Roofing INC. is published. One employer, no account, unsubscribe in one click.
Site address
2355 CRAGMOOR RD.
City
BOULDER
State
CO
ZIP
80305
Mailing
3551 PEARL ST., BOULDER, CO 80301
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
30
Ownership type
A

4 citations on file for this inspection.

1926.502 F01

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 28, 2014
Abate by
Feb 15, 2014
Penalty
Initial $3,570 · Current $1,785 Reduced
29 CFR 1926.502(f)(1): Warning lines were not erected around all sides of the roof work area:       (a) Boulder Roofing, Inc. @ 2355 Cragmoor Rd, Boulder, CO 80305: On and  before January 13th, 2014, the exposing employer did not ensure that the warning line system that was being utilized as a fall protection system for employees conducting roofing activities on the flat roof a single-family home, was erected around all sides of the roof. The warning line system used was not erected on the west and north side of the flat roof where employees were working. This condition exposed employees to a fall hazard of approximately 18' on the west and north side of the roof.
Recent events (2)
  • · I (S) $1785
  • · Z (S) $3570

1926.502 F01 I

Other-than-serious 1 instance 4 exposed
Issued
Jan 28, 2014
Abate by
Feb 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926. 502(f)(1)(i): Warning lines were not erected less than 6 feet (1.8 M) from the roof edge.   (a)    Boulder Roofing, Inc., 2355 Cragmoor Rd., Boulder, CO 80305: On and before January 13, 2014, the employer did not ensure that the warning line ws a minimum of 6 feet from the edge. The warning line was approximately 5 feet from the edge.       Abatement Note:  Abatement certification is required for this item (see enclosed Abatement-Certification Letter").
Recent events (2)
  • · I (O) $0
  • · Z (S) $0

1926.502 F01 III

Other-than-serious 1 instance 4 exposed
Issued
Jan 28, 2014
Abate by
Feb 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926. 502(f)(1)(iii): Points of access, materials handling areas, storage areas, and hoisting areas were not connected to the work area by an access path formed by two warning lines.  (a)    Boulder Roofing, Inc., 2355 Cragmoor Rd., Boulder, CO 80305: On and before January 13, 2014, the employer did not ensure that the access point to the roof was connected to the warning line system. This condition exposed the employees to a fall in excess of 6 feet.      Abatement Note:  Abatement certification is required for this item (see enclosed Abatement-Certification Letter").
Recent events (2)
  • · I (O) $0
  • · Z (S) $0

1926.1052 C04 I

Serious Gravity 1 1 instance 4 exposed
Issued
Jan 28, 2014
Penalty
Initial $1,785 · Current $893 Reduced
29 CFR 1926.1052(c)(4)(i): Midrails were not located at a height midway between the top edge of the stairrail system and the stairway steps.      (a)    Boulder Roofing Inc., 2355 Cragmoor Rd., Boulder, CO 80305: On and before January 13, 2014, as an exposing contractor onsite, Boulder Roofing, Inc. did not ensure that an adequate midrail was installed on the stairway leading to the second level of a residential remodel. This condition exposed employees to a fall hazard.      Abatement Note:  Abatement certification is not required for this item (see enclosed Abatement-Certification Letter").
Recent events (2)
  • · I (S) $893
  • · Z (S) $1785

View Boulder Roofing INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339544967.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.