Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EAST WEST SEAFOODS LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of EAST WEST SEAFOODS LLC in ISA DOCK, KODIAK, AK 99615 (NAICS 311712). OSHA activity number 339567125.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch East West Seafoods LLC — free Get an email when a new federal OSHA severe-injury report for East West Seafoods LLC is published. One employer, no account, unsubscribe in one click.
Site address
ISA DOCK
City
KODIAK
State
AK
ZIP
99615
Mailing
P O BOX 124, KODIAK, AK 99615
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311712
Employees
25
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 27 instances 25 exposed
Issued
Feb 5, 2014
Abate by
Mar 6, 2014
Penalty
Initial $2,520 · Current $2,520
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees.  F/V Pacific Producer; on or about 29 January 2014 and times prior thereto; twenty-seven instances were noted where electrical hazards existed:      (a) Upper deck sleeping quarters; an energized overhead florescent lamp had standing water intrusion inside of the protective cover.         (b) Upper deck sleeping quarters, port side, aft lower bunk area, right hand side; an electrical outlet box had exposed energized electrical wires that were not guarded.         (c) Upper deck sleeping quarters, port side, aft upper bunk area, left hand side; an energized electrical outlet switch was missing the protective cover.         (d) Upper deck sleeping quarters, port side, adjacent to toilet; right hand side; exposed energized electrical wires to a hard-wired electrical heater unit was missing the protective cover.          (e) Upper deck sleeping quarters, port side, between two sinks; an energized electrical outlet was missing the protective cover.         (f) Upper deck sleeping quarters, port side, forward upper bunk area, right hand side; an electrical outlet box had energized electrical wires that were not guarded.         (g) Upper deck sleeping quarters, port side, center upper bunk area, right hand side; an electrical outlet box had energized electrical wires were not guarded.         (h) Upper deck sleeping quarters, port side, center upper bunk area, right hand side; an energized electrical outlet was missing the protective cover.         (i) Upper deck sleeping quarters, port side, center upper bunk area, right hand side; an energized incandescent light bulb was not guarded.         (j) Upper deck sleeping quarters, port side, center upper bunk area, right hand side; an energized electrical outlet box was missing the protective cover.         (k) Upper deck sleeping quarters, port side, upper bunk area, left hand side; an electrical outlet box had energized electrical wires that were not guarded.         (l) Upper deck sleeping quarters, port side, upper bunk area, right back side; an energized electrical outlet box was missing the protective cover.         (m) Upper deck sleeping quarters, port side, center lower bunk area, right hand side; an energized incandescent light bulb was not guarded.         (n) Upper deck sleeping quarters, portside, between the bunks; an energized incandescent light bulb was not guarded.         (o) Upper deck sleeping quarters, port side, adjacent to toilet; right hand side; exposed energized electrical wires to a hard-wired electrical heater unit was missing the protective cover.          (p) Upper deck sleeping quarters, starboard side, adjacent to entryway; exposed energized electrical wires to a hard-wired electrical heater unit was missing the protective cover.          (q) Upper deck sleeping quarters, starboard side, adjacent to sink; left hand side; a flexible extension cord was used as permanent wiring.         (r) Entry way to the engine room, right hand side; a 220 volt electrical panel was not labeled indicating its use and purpose.         (s) Bow area, starboard side, refrigerator and compressor area; an electrical box conduit connector was separated from the junction box. Outlet was energized.          (t) Bow area, starboard side, refrigerator and compressor area; an electrical drop light, with an incandescent bulb, was missing the protective cover.          (u) Bow area, starboard side, refrigerator and compressor area; an electrical drop light had damaged to the protective insulation on the cord.          (v) Bow area, starboard side, refrigerator and compressor area; the compressor had an energized electrical panel that was missing its protective cover.         (w) Galley area; seven overhead florescent lights approximately 75 inches from the floor, were missing the protective covers.         (x) Engine room, forward area; an energized electrical outlet box had evidence of arcing and overheating.          (y) Laundry room area; overhead florescent lights approximately 71 inches from the floor, were missing the protective cover.         (z) Laundry room area; an energized electrical outlet box was damaged. A portion of the face plate was broken off.         (aa) Engine room area; an energized electrical bus panel was missing protective cover.      These conditions exposed employees to electrical shock and electrical burn hazards and electrocution.
Recent events (1)
  • — Z (S) $2520

1910.212 A05

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 5, 2014
Abate by
Mar 6, 2014
Penalty
Initial $1,080 · Current $1,080
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch.  F/V Pacific Producer, office area, on or about 29 January 2014 and times prior thereto; a Markel, Model HF3185, electric heater fan blade was not guarded. This condition exposed employees to a caught in hazard.
Recent events (1)
  • — Z (S) $1080

1910.101 B

Other-than-serious 2 instances 2 exposed
Issued
Feb 5, 2014
Abate by
Mar 6, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6.  F/V Pacific Producer, bow, starboard side, refrigerator and compressor area; on or about 29 January 2014 and times prior thereto; compressed gas cylinders of chlorodifluoromethane were not stored with the protective cap installed. This condition exposed employees to inhalation of toxic substances.
Recent events (1)
  • — Z (O) $0

View East West Seafoods LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339567125.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.