KODIAK, AK —
OSHA Inspection: EAST WEST SEAFOODS LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of EAST WEST SEAFOODS LLC in MV PACIFIC PRODUCERS SUITE 116, KODIAK, AK 99619 (NAICS 311710). OSHA activity number 346083819.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EAST WEST SEAFOODS LLC
- Site address
- MV PACIFIC PRODUCERS SUITE 116
- City
- KODIAK
- State
- AK
- ZIP
- 99619
- Mailing
- P.O. BOX 141934, ANCHORAGE, AK 99514
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311710
- Employees
- 27
- Ownership type
- A
Citations
25 citations on file for this inspection.
1910.141 A03 I
- Issued
- Jan 12, 2023
- Abate by
- Feb 23, 2023
- Penalty
- Initial $9,572 · Current $9,572
General-duty citation text
29 CFR 1910.141(a)(3)(i): Places of employment were not kept clean to the extent that the nature of the work allowed: a) Fish Processing Room - On or about July 20, 2022, employees processed salmon utilizing a Ryco Salmon Gutter, model #645F and a Ryco Salmon Header, model #226B. Employees were exposed to health hazards due to fish biproducts and other material remaining after the sanitation process and visible on inside of the conveyor area. b) Stateroom 7 - On or about July 20, 2022, and times prior thereto, the wall and floor area of the latrine were not cleaned, exposing employees to health hazards.
Recent events (3)
- — J (S) $9572
- — C (S) $9572
- — Z (S) $9572
1910.141 D01
- Issued
- Jan 12, 2023
- Abate by
- Feb 23, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.141(d)(1): Washing facilities were not maintained in a sanitary condition: a) Laundry Room - On or about July 20, 2022, housekeeping was not performed with unsanitary conditions of toilet facilities and showers, exposing employees to health hazards.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.141 B01 I
- Issued
- Jan 12, 2023
- Abate by
- Feb 23, 2023
- Penalty
- Initial $11,167 · Current $11,167
General-duty citation text
29 CFR 1910.141(b)(1)(i): Potable water was not provided in all places of employment, for drinking, washing of the person, cooking, washing of foods, washing of cooking or eating utensils, washing of food preparation or processing premises, and personal service rooms. a) Stateroom 2, 4-7, 11, and 12: On or about July 20, 2022, and times prior thereto, employees were provided and utilized a shower and sink basin with non-potable water provided for washing, exposing employees to biological health hazards. b) Laundry Room community shower: On or about July 20, 2022, and times prior thereto, employees were provided and utilized a shower and wash machine with non-potable water for washing of persons, exposing them to biological hazards. c) Galley: On or about July 20, 2022, and times prior thereto, non-potable water was used for washing of food, washing the food preparation area, and washing of dishes, exposing employees to biological hazards. d) Processing Line: On or about July 20, 2022, and times prior thereto, non-potable water was used for processing fish and cleaning the fish equipment area, exposing employees to biological hazards.
Recent events (3)
- — J (S) $11167
- — C (S) $11167
- — Z (S) $11167
1910.141 G04
- Issued
- Jan 12, 2023
- Abate by
- Feb 23, 2023
- Penalty
- Initial $9,572 · Current $9,572
General-duty citation text
29 CFR 1910.141(g)(4): Food or beverages were stored in area(s) exposed to toxic material(s): a) Dry Storage - On or about July 20, 2022, and times prior thereto, employees consumed food which was stored in dry storage and the ceiling had leaking water from the processing equipment above it during sanitation, exposing employees to health hazards. b) Galley - On or about July 20, 2022, and times prior thereto, employees consumed food from serving trays stored below damaged area of leaky roof and insultation material unsecured, exposing employees to health hazards.
Recent events (3)
- — J (S) $9572
- — C (S) $9572
- — Z (S) $9572
1910.151 C
- Issued
- Jan 12, 2023
- Abate by
- Feb 23, 2023
- Penalty
- Initial $6,381 · Current $6,381
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) Chemical Closet Storage - On or about July 20, 2022, employees transferred chemicals such as, Sanite 75 and FRM 63 CB without an eyewash or shower, exposing employees to corrosive hazards. b) Fish Processing Room - On or about July 20, 2022, employees applied chemicals to fish processing equipment for sanitation and cleaning such as Sanite 75 and FRM 63 CB without an eyewash or shower, exposing employees to corrosive hazards.
Recent events (3)
- — J (S) $6381
- — C (S) $6381
- — Z (S) $6381
1910.303 B02
- Issued
- Jan 12, 2023
- Abate by
- Feb 23, 2023
- Penalty
- Initial $11,167 · Current $11,167
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Wheelhouse - On or about October 25, 2022, and times prior thereto, employees utilized a relocatable power tap connected in series to a second relocatable power tap on the wall facing the stern of the vessel. Power source was used to power multiple heaters, exposing employees to electrical and fire hazards. b) Wheelhouse - On or about October 25, 2022, and times prior thereto, employees utilized a relocatable power tap connected in series to a second relocatable power tap on the wall facing the bow of the vessel. Power source was used to power a printer, exposing employees to electrical and fire hazards. c) Captains Room - On or about October 25, 2022, and times prior thereto, an employee utilized a relocatable power tap for power of appliances to include microwave and fridge. The relocatable power tap had been permanently affixed to flexible cord attached to the wall powering the outlet for use, exposing employees to electrical and fire hazards. d) Room 2 - On or about October 25, 2022, and times prior thereto, the Owner and Managing member of the pacific producer had permanently affixed a relocatable connected in series to a second relocatable power tap on the wall with sink and mirror. The relocatable power taps were for use of powering devices such as lighting fixtures and phone chargers, exposing employees to fire and electrical hazards. e) Oficina - On or about October 25, 2022, and times prior thereto, the Owner and managing member of the Pacific Producer had permanently affixed and utilized multiple relocatable power taps as an additional outlet source for microwave, chargers, and computer equipment. g) Main Deck/Outside Galley - On or about October 25, 2022, and times prior thereto, an outlet receptacle was not used in accordance with listing and labeling when installed and used with series connection of extension cords and was placed on the floor when utilized as a power source for refrigerators, exposing employees to electrical and fire hazards. h) Main Deck/Outside Galley - On or about October 25, 2022, and times prior thereto, extension cords were connected together in series outside, and a second extension cord was modified at the female end and hardwired for permanent installation into an outlet receptable, exposing employees to electrical and fire hazards.
Recent events (3)
- — J (S) $11167
- — C (S) $11167
- — Z (S) $11167
1910.305 A02 VI
- Issued
- Jan 12, 2023
- Abate by
- Feb 23, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(a)(2)(vi): Receptacles used on the end of flexible cords were not of the grounding type. a) F/V Pacific Producer - On or about July 20, 2022, and times prior thereto, receptacles used throughout areas of the vessel were installed at the end of flexible cords, with the receptacles not of grounding type, exposing employees to electrical hazards.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.303 B07 I
- Issued
- Jan 12, 2023
- Abate by
- Feb 23, 2023
- Penalty
- Initial $11,167 · Current $11,167
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxillary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment: a) Stateroom 6 - On or about July 20, 20222, and times prior thereto, an outlet receptable installed for use had a damaged cover allowing for opening and was not effectively closed, exposing employees to electrical and fire hazards. b) Pump Room/Worktable - On or about September 29, 2022, and times prior thereto, openings were observed with knockouts missing for breaker spaces 5 and 7, exposing employees to electrical and fire hazards. c) Engine Room - On or about October 2, 2022, and times prior thereto, openings were observed with knockouts missing for breaker spaces 15, 17, and 19, exposing employees to electrical and fire hazards. d) Stateroom 2 - On or about October 25, 2022, and times prior thereto, a housing unit for a heater was observed with unused openings not effectively closed with a missing knockout and cover, exposing employees to electrical and fire hazards. e) Stateroom 2 - On or about October 25, 2022, and times prior thereto, a metal light housing permanently installed was observed with an unused opening at the socket, exposing employees to electrical hazards. f) Stateroom 8 - On or about October 25, 2022, and times prior thereto, a subpanel was observed with unused openings not effectively closed between the top and bottom of the cover, exposing employees to electrical hazards.
Recent events (3)
- — J (S) $11167
- — C (S) $11167
- — Z (S) $11167
1910.303 C03 I
- Issued
- Jan 12, 2023
- Abate by
- Feb 23, 2023
- Penalty
- Initial $11,167 · Current $11,167
General-duty citation text
29 CFR 1910.303(c)(3)(i): All splices and joints and the free ends of the conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose. a) Wheelhouse - On or about July 20, 2022, and times prior thereto, conductors of TSGU-4 10AWG/4 power cable were spliced to conductors of a BC-5W2 marine boat cable with use of a splice connector and were not covered with an insulation, exposing employees to electrical and fire hazards. b) Wheelhouse - On or about July 20, 2022, and times prior thereto, conductors of a BC-5W2 14AWG/2 marine boat cable were spliced with conductors of a blue strobe light and a bell alarm manufactured by Aqualarm for hardwiring and were not covered with insulation, exposing employees to electrical and fire hazards. c) Stateroom 4 - On or about July 20, 2022, and times prior thereto, electrical tape was used to cover electrical conductors for flexible wiring of an exhaust fan and heater spliced to a BC-522 14AWG/2 flexible cord exiting a hole in the ceiling providing power from a circuit breaker, exposing employees to electrical and fire hazards. d) Galley Kitchen - On or about September 29, 2022, and times prior thereto, a braided flexible cord on top of the oven exhaust was observed spliced at ends with wire gauge caps installed and electrical tape placed over parts of the conductors, exposing employees to electrical and fire hazards. e) Pump room - On or about September 29, 2022. and times prior thereto, flexible cords were observed spliced for a quadplex receptacle unit adjacent to the exhaust stack. Electrical tape was placed over conductors, exposing employees to electrical and fire hazards. f) Stateroom 2 - On or about October 25. 2022, and times prior thereto, the free ends of conductors of an overhead light receptable located above the sink were covered with electrical tape, exposing employees to electrical and fire hazards. g) Stateroom 2 - On or about October 25, 2022, and times prior thereto, a 10AWG braided sheathed cable had free ends of three conductors exposed and covered with electrical tape, exposing employees to electrical and fire hazards. h) Stateroom 2 - On or about October 25, 2022, and times prior thereto, electrical conductors of a 14AWG flexible cord were spliced to electrical conductors in an open junction box receded into the wall near the ceiling and were not covered with insulation, exposing employees to electrical and fire hazards. i) Stateroom 2 - On or about October 25, 2022, and times prior thereto, a light fixture at the ceiling was hardwired with the conductors of the fixture and the conductors of a light switch below spliced and connected to 14 AWG flexible cord secured to the ceiling area and was not covered with insulation, exposing employees to electrical and fire hazards. j) Stateroom 2 - On or about October 25, 2022, and times prior thereto, a 14 AWG flexible cord painted white was observed attached to the ceiling and had conductors spliced without proper insulation covering the open ends of the conductors, exposing employees to overhead electrical hazards. k) Stateroom 8 Storage - On or about October 25, 2022, and times prior thereto, a 14 AWG flexible cord was spliced and connected to a light fixture and light switch receptable at the ceiling area and the conductor ends were covered with electrical tape, exposing employees to electrical and fire hazards. l) Stateroom 9 - On or about October 25, 2022, and times prior thereto, a 14 AWG flexible cord was observed spliced with the conductors covered with painters' tape, exposing employees to electrical and fire hazards.
Recent events (3)
- — J (S) $11167
- — C (S) $11167
- — Z (S) $11167
1910.303 E01 II
- Issued
- Jan 12, 2023
- Abate by
- Feb 23, 2023
- Penalty
- Initial $6,381 · Current $6,381
General-duty citation text
29 CFR 1910.303(e)(1)(ii): Other markings giving voltage, current, wattage, or other ratings as necessary. a) Wheelhouse - On or about July 20, 2022, and times prior thereto, an electrical panel labeled Wheel House Fuse Box was not marked or labeled providing voltage, current, wattage, and other ratings as necessary, exposing employees to electrical hazards. b) Wheelhouse - On or about July 20, 2022, and times prior thereto, a fuse box was not marked or labeled providing voltage, current, wattage, and other ratings as necessary, exposing employees to electrical hazards. c) Wheelhouse - On or about July 20, 2022, and times prior thereto, an electrical panel containing branch circuits for flood lights and other various items was not marked or labeled providing voltage, current, wattage, and other ratings necessary, exposing employees to electrical hazards. d) Forward Cold Storage Area - On or about September 29, 2022, and times prior thereto, an electrical panel was observed without markings or labeling providing voltage, current, wattage, and other ratings necessary, exposing employees to electrical hazards. e) Pump Room - On or about September 29, 2022, and times prior thereto, two electrical panels were observed without markings or labeling to provide voltage, current, wattage, and other ratings necessary, exposing employees to electrical hazards. f) Oficina - On or about October 25, 2022, and times prior thereto, a subpanel was observed without markings or labeling providing voltage, current, wattage, and other ratings necessary, exposing employees to electrical hazards.
Recent events (3)
- — J (S) $6381
- — C (S) $6381
- — Z (S) $6381
1910.303 F02
- Issued
- Jan 12, 2023
- Abate by
- Feb 23, 2023
- Penalty
- Initial $7,977 · Current $7,977
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a) Wheelhouse/Breaker 3 - On or about July 20, 2022, and times prior thereto, a 20 AMP circuit breaker was observed in electrical panel labeled Wheel House Fuse Box. The circuit breaker was not labeled to indicate its purpose nor was it arranged so the purpose was evident, exposing employees to electrical hazards. b) Wheelhouse/Breaker 4 - On or about July 20, 2022, and times prior thereto, a 20 AMP circuit breaker was observed in electrical panel labeled Wheel House Fuse Box. The circuit breaker was not labeled to indicate its purpose nor was it arranged so the purpose was evident, exposing employees to electrical hazards. c) Wheelhouse/Breaker 16 - On or about July 20, 2022, and times prior thereto, a 60 AMP circuit breaker was observed in electrical panel labeled Wheel House Fuse Box. The circuit breaker was not labeled to indicate its purpose nor was it arranged so the purpose was evident, exposing employees to electrical hazards. d) Wheelhouse/Breaker 20 - On or about July 20, 2022, and times prior thereto, a 20 AMP circuit breaker was observed in electrical panel labeled Wheel House Fuse Box. The circuit breaker was not labeled to indicate its purpose nor was it arranged so the purpose was evident, exposing employees to electrical hazards. e) Laundry Room/Breaker 19 - On or about July 20, 2022, and times prior thereto, a 20 AMP circuit breaker was observed in the on position in an electrical panel. The circuit breaker was not labeled to indicate its purpose and was not arranged so the purpose was evident, exposing employees to electrical hazards. f) Forward Cold Storage/Breakers Throughout - On or about September 29, 2022, and times prior thereto, circuit breakers were observed without labeling to indicate their purpose nor were they arranged so the purpose was evident, exposing employees to electrical hazards. g) Engine Room/Breaker 14 - On or about October 2, 2022, and times prior thereto, a 20 AMP circuit breaker was observed in the on position in an electrical panel. The circuit breaker was not labeled to indicate its purpose and was not arranged so the purpose was evident, exposing employees to electrical hazards. h) Stateroom 8/Breaker 11 - On or about October 25, 2022, and times prior thereto, a 20 AMP circuit breaker was observed in the on position in an electrical panel. The circuit breaker was not labeled to indicate its purpose and was not arranged so the purpose was evident, exposing employees to electrical hazards. i) Stateroom 8/Breaker 20 - On or about October 25, 2022, and times prior thereto, a 20 AMP circuit breaker was observed installed in an electrical panel and was not labeled to indicate its purpose and was not arranged so the purpose was evident, exposing employees to electrical hazards.
Recent events (3)
- — J (S) $7977
- — C (S) $7977
- — Z (S) $7977
1910.303 G01
- Issued
- Jan 12, 2023
- Abate by
- Feb 23, 2023
- Penalty
- Initial $7,977 · Current $7,977
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) Wheelhouse - On or about July 20, 2022, and times prior thereto, a chair, desk, printer, and cardboard boxes were stored had in front of the wheelhouse breaker panel box containing fuses, marked "wheelhouse fuse box" and a circuit break panel for flood lighting, exposing employees to electrical and fire hazards. b) Laundry Room - On or about July 20, 2022, and times prior there, a washing machine with bags of clothing had been placed in front of a panel containing breakers for the washer, heater, and dryers, exposing employees to electrical and fire hazards. c) Fish Processing Room - On or about July 20, 2022, and times prior thereto, a metal pan and plastic containers were placed and stored in front of the 120/240V panel marked CB-1 and the 480V panel marked Factory, exposing employees to electrical and fire hazards.
Recent events (3)
- — J (S) $7977
- — C (S) $7977
- — Z (S) $7977
1910.304 B03 I
- Issued
- Jan 12, 2023
- Abate by
- Feb 23, 2023
- Penalty
- Initial $11,167 · Current $11,167
General-duty citation text
29 CFR 1910.304(b)(3)(i): All 125-volt, single-phase, 15- and 20-ampere receptacles installed in wet locations were not equipped with ground-fault circuit-interrupter protection for personnel. a) F/V Pacific Producer - On or about July 20, 2022, and times prior thereto, employees used 120 outlet receptacles throughout the vessel which had multiple leaks in roofing, flooring, and was not water-tight. The receptacles installed and used were not GFCI protected exposing employees to electrical hazards.
Recent events (3)
- — J (S) $11167
- — C (S) $11167
- — Z (S) $11167
1910.305 A02 IX
- Issued
- Jan 12, 2023
- Abate by
- Feb 23, 2023
- Penalty
- Initial $6,381 · Current $6,381
General-duty citation text
29 CFR 1910.305(a)(2)(ix): All lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lampholder with a guard. Brass shell, paper-lined sockets, or other metal-cased sockets may not be used unless the shell is grounded. a) Stateroom 9 - On or about July 20, 2022, and times prior thereto, the employer had provided employees an aluminum shell light fixture for use without grounding, exposing employees to electrical hazards. b) Laundry Room - On or about July 20, 2022, and times prior thereto, incandescent light bulbs used for in a light fixture were not covered to prevent accidental contact, exposing employees to flying projectile hazards. c) Stateroom 11 - On or about September 29, 2022, and times prior thereto, two light fixtures used with incandescent light bulbs were not covered to prevent accidental contact, exposing employees to flying projectile hazards. d) Stateroom 2 - On or about October 25, 2022, and times prior thereto, an incandescent clamp light with aluminum reflective housing was used without cover prevent accidental contact. The fixture was also used without grounding, exposing employees to flying projectiles and electrical hazards. e) Stateroom 8 Storage - On or about October 25, 2022, and times prior thereto, incandescent light bulbs in a lighting fixture were not covered or guarded to prevent from accidental contact, exposing employees to flying projectile hazards.
Recent events (3)
- — J (S) $6381
- — C (S) $6381
- — Z (S) $6381
1910.305 B02 I
- Issued
- Jan 12, 2023
- Abate by
- Feb 23, 2023
- Penalty
- Initial $11,167 · Current $11,167
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: a) Main Deck/Outside Galley - On or about October 25, 2022, and times prior thereto, an outlet receptacle was observed without a cover with open energized electrical wiring, exposing employees to electrical hazards.
Recent events (3)
- — J (S) $11167
- — C (S) $11167
- — Z (S) $11167
1910.305 E01
- Issued
- Jan 12, 2023
- Abate by
- Feb 23, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed to prevent moisture or water from entering and accumulating within the enclosures: a) Oficina - On or September 29, 2022, and times prior thereto, a subpanel fed from the laundry room panel was not provided proper enclosure for a damp and wet location allowing moisture and water to enter, exposing employees to electrical and fire hazards.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.305 D02
- Issued
- Jan 12, 2023
- Abate by
- Feb 23, 2023
- Penalty
- Initial $11,167 · Current $11,167
General-duty citation text
29 CFR 1910.305(d)(2): Panelboards were not dead front: a) Fish Processing Room - On or about July 20, 2022, and times prior thereto, a 120/240V main circuit breaker panel had exposed electrical and was not dead front, exposing employees to electrical hazards. b) Fish Processing Room - On or about July 20, 2022, and times prior thereto, a 480V circuit breaker sub-panel fed from below bow and labeled Factory had exposed electrical and was not dead front, exposing employees to electrical hazards. c) Fish Processing Room - On or about July 20, 2022, and times prior thereto, a 480V circuit breaker panel containing a circuit for the transformer, junction box C, receptacle plug A, and junction box B was not dead front, exposing employees to electrical hazards. d) Forward Cold Storage - On or about September 29, 2022, and times prior thereto, an unmarked panel near the entrance was found without dead front, exposing employees to electrical hazards.
Recent events (3)
- — J (S) $11167
- — C (S) $11167
- — Z (S) $11167
1910.305 G01 IV A
- Issued
- Jan 12, 2023
- Abate by
- Feb 23, 2023
- Penalty
- Initial $11,167 · Current $11,167
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): As a substitute for the fixed wiring of a structure. a) F/V Pacific Producer/Throughout - On or about July 20, 2022, flexible cords and cables of various gauges were installed and used as a substitute for fixed wiring throughout the vessel providing connection and electrical power supply to lighting fixtures, outlet receptacles, junction boxes, and subpanels, and other electrical for employee use, exposing employees to electrical and fire hazards.
Recent events (3)
- — J (S) $11167
- — C (S) $11167
- — Z (S) $11167
1910.305 G01 IV B
- Issued
- Jan 12, 2023
- Abate by
- Feb 23, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables were run through holes in walls, ceilings, or floors: a) Wheelhouse - On or about July 20, 2022, and times prior thereto, multiconductor flexible cords of various gauges were used as a substitute for fixed wiring and was observed attached with zip ties along the walls and ceiling. The cables exited the wheelhouse to the exterior through two holes in the wall above the door frame, exposing employees to electrical and fire hazards. b) Stateroom 4/Bunk Wall - On or about July 20, 2022, and times prior thereto, 14 AWG flexible cable painted white was observed running from the head wall to side wall inside of the crew bunk space to provide power to an outlet receptacle installed providing power supply to a lamp fixture, exposing employees to electrical and fire hazards. c) Captains Room - On or about October 24, 2022, and times prior thereto, 10AWG braided cable and 14AWG braided cable, both painted white, were attached together with the use of metal cable clamps and zip ties. Both cables were used as substitute for permanent wiring and were running into the room from the exterior and was observed attached to the ceiling and walls for connection to light switch, lighting fixture, outlet receptables, a heater shell, and junction boxes, exposing employees to electrical and fire hazards. d) Stateroom 2 - On or about, October 25, 2022, and times prior thereto, 10AWG braided cable and 14 AWG flexible cable had been painted white and were observed running along the walls and ceilings secured with use of metal cable clamps and screws. The cables were run through holes in the wall and were used as a substitute for fixed wiring providing power supply to a light switch, light fixture, and outlet receptables, exposing employees to electrical and fire hazards. e) Stateroom 8 - On or about October 25, 2022, and times prior thereto multiple 14 AWG flexible cords hardwired to light receptable were observed exiting the room through holes in the wall, exposing employees to electrical and fire hazards. f) Stateroom 8 - On or about October 25, 2022, and times prior thereto, a black 14AWG flexible cord observed for power supply of an outlet fixture installed for use was observed running through a hole in the wall, exposing employees to electrical and fire hazards. g) Stateroom 8 - On or about October 25, 2022, and times prior thereto, a flexible cord used for wiring of a dual outlet receptable, and light fixture unit was observed running through a wall opening, exposing employees to electrical hazards. h) Stateroom 8 - On or about October 25, 2022, and times prior thereto, a flexible cord attached to a light fixture was observed running through a hole in the ceiling, exposing employees to electrical and fire hazards. i) Stateroom 8 - On or about October 25, 2022, and times prior thereto, flexible cable painted white ran along the exterior wall and into a hole to the interior for connection of a sub-fed control panel, exposing employees to electrical and fire hazards. j) Stateroom 9 - On or about July 20, 2022, and times prior thereto, a flexible 14 AWG painted cord was observed entering through a hole above the sink wall and exiting in a hole in the ceiling, exposing employees to electrical and fire hazards. k) Stateroom 10 - On or about July 20, 2022, and times prior thereto, flexible cords painted white had been ran through holes placed in the walls, exposing employees to electrical and fire hazards.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.305 G01 IV E
- Issued
- Jan 12, 2023
- Abate by
- Feb 23, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(E): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used: Where concealed behind building walls, ceilings, or floors. a) Stateroom 7 - On or about July 20, 2022, and times prior thereto, a 14 AWG flexible cord painted white was observed running along the walls and was concealed behind the wood bunk assembly installed on the wall, exposing employees to electrical and fire hazards. b) Stateroom 9 - On or about July 20, 2022, and times prior thereto, a flexible cord used for power supply to outlet receptacles was observed running into a hole opening behind wall of storage compartment next to bunk space and was concealed until observed exit at the back of the storage unit at the head of the top bunk, exposing employees to electrical and fire hazards. c) Main Deck/Galley - On or about October 25, 2022, and times prior thereto, and times prior thereto, the employer had installed and used flexible cables and cords sourced from control panels in the wheelhouse underneath the main decking to provide power to lower levels, exposing employees to electrical and fire hazards.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.305 G02 II
- Issued
- Jan 12, 2023
- Abate by
- Feb 23, 2023
- Penalty
- Initial $11,167 · Current $11,167
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: a) F/V Pacific Producer/Throughout - On or about July 20, 2022, and times prior thereto, flexible cords were observed used in continuous lengths with splices to conductors and taps to other flexible cords providing electrical power supply throughout various parts areas of the vessel.
Recent events (3)
- — J (S) $11167
- — C (S) $11167
- — Z (S) $11167
1910.305 J01 IV
- Issued
- Jan 12, 2023
- Abate by
- Feb 23, 2023
- Penalty
- Initial $11,167 · Current $11,167
General-duty citation text
29 CFR 1910.305 (j)(1)(iv): Fixtures installed in wet or damp locations were not approved for the purpose and were not so constructed or installed that water could not enter or accumulate in wireways, lamp holders or other electrical parts: a) Oficina - On or about September 29, 2022, and times prior thereto, a light fixture was installed and used in a wet and damp location due to the roof leaking with clear plastic secured around the fixture to capture accumulating water leaking, exposing employees to electrical and fire hazards.
Recent events (3)
- — J (S) $11167
- — C (S) $11167
- — Z (S) $11167
1910.134 C01
- Issued
- Jan 12, 2023
- Abate by
- Feb 23, 2023
- Penalty
- Initial $22,333 · Current $22,333
General-duty citation text
29 CFR 1910.134(c)(1): The employer did not establish and implement a written respiratory protection program with worksite-specific procedures in any workplace where respirators were necessary to protect the health of the employee or whenever respirators were required by the employer: a) F/V Pacific Producer, where the employer provided and required respirators be used by employees to include but not limited to, MSA gas masks, self-contained breathing apparatus (SCBA), and 3M and Honeywell half-face respirators. The employer did not develop and implement a written respiratory program, exposing employees to chemical and other health hazards. East West Seafood's LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.134(c)(1), which was contained in OSHA inspection number 1295664, citation number 1, item number 3a, and was affirmed as a final order on April 4, 2019, with respect to a workplace located at F/V Pacific Producer at 7001 Seaview Ave N.W., Seattle, WA 98117.
Recent events (3)
- — J (R) $22333
- — C (R) $22333
- — Z (R) $22333
1910.1200 E01
- Issued
- Jan 12, 2023
- Abate by
- Feb 23, 2023
- Penalty
- Initial $19,144 · Current $19,144
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): a) F/V Pacific Producer - On or about July 20, 2022, the employer did not provide a hazard communications program for employees working on the vessel, to include, but not limited to, ammonia, rust remover and acid cleaner, Sanite 75, disinfectant, and FRM 63 CB, exposing employees to health and fire hazards. East West Seafood's LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.1200(e)(1), which was contained in OSHA inspection number 1295664, repeat citation number 2, item number 1, and was affirmed as a final order on April 4, 2019, with respect to a workplace located at F/V Pacific Producer at 7001 Seaview Ave N.W., Seattle, WA 98117.
Recent events (3)
- — J (R) $19144
- — C (R) $19144
- — Z (R) $19144
1904.40 A
- Issued
- Jan 12, 2023
- Abate by
- Feb 23, 2023
- Penalty
- Initial $1,595 · Current $1,595
General-duty citation text
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours. a) F/V Pacific Producer - On or about July 20, 2022, the employer failed to provide copies of the injury and illness records to an authorized representative.
Recent events (3)
- — J (O) $1595
- — C (O) $1595
- — Z (O) $1595
More inspections at East West Seafoods LLC
View East West Seafoods LLC's full OSHA safety record →
More inspections in this industry (NAICS 311710)
More inspections in AK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346083819.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.