OSHA Inspection: REAL CONSTRUCTION, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of REAL CONSTRUCTION, LLC in 1001 SOUTH 17TH STREET, PHILADELPHIA, PA 19147 (NAICS 238910). OSHA activity number 339573057.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Real Construction, LLC — free Get an email when a new federal OSHA severe-injury report for Real Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1001 SOUTH 17TH STREET
City
PHILADELPHIA
State
PA
ZIP
19147
Mailing
7710 CASTOR AVENUE, PHILADELPHIA, PA 19152
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
7
Ownership type
A

6 citations on file for this inspection.

1926.100 A

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 21, 2014
Penalty
Initial $3,080 · Current $3,080
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling objects:  a) 1001 South 17th Street, Philadelphia, PA - An employee was working in an excavation, approximately 70 feet long by 70 feet wide and 10 feet deep, and was not wearing head protection, thus exposing the employee to the danger of head injuries. This violation was observed on or about January 17, 2013.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
  • — Z (S) $3080

1926.651 C02

Serious Gravity 10 1 instance 5 exposed
Issued
Mar 21, 2014
Abate by
Mar 27, 2014
Penalty
Initial $3,080 · Current $3,080
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:  a) 1001 South 17th Street, Philadelphia, PA - The employees were working in an excavation approximately 70 feet long by 70 feet wide and 10 feet deep without having a means of egress from the excavation, thus exposing the employees to trip/falls/cave-in hazards. This violation was observed on or about January 17, 2013.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
  • — Z (S) $3080

1926.651 I03

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 21, 2014
Abate by
Mar 27, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.651(i)(3): Sidewalks had been undermined and a support system or another method was not provided to protect employees from the possible collapse of such structures:  a) 1001 South 17th Street, Philadelphia, PA - The employees were working in an excavation approximately 70 feet long by 70 feet wide and 10 feet deep in which the sidewalk was undermined and a support system was not installed to protect the employees from a possible collapse. This condition exposed the employees to struck-by hazards. This violation was observed on or about January 17, 2013.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
  • — Z (S) $0

1926.651 K02

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 21, 2014
Penalty
Initial $3,080 · Current $3,080
29 CFR 1926.651(k)(2): Where the competent person found evidence of a situation that could result in a possible cave-in, exposed employees were not removed from the hazardous area until the necessary precautions have been taken to ensure their safety:  a) 1001 South 17th Street, Philadelphia, PA - The competent person did not make an assessment to determine the possibility of cave-in hazards or other hazardous conditions to ensure that employees working in or around the excavation were removed from cave-in/struck-by hazards. This violation was observed on or about January 17, 2013.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
  • — Z (S) $3080

1926.651 J02

Serious Gravity 10 1 instance 5 exposed
Issued
Mar 21, 2014
Penalty
Initial $3,080 · Current $3,080
29 CFR 1926.651(j)(2): Employees were not protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection by placing and keeping such materials or equipment at least 2 feet from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary was not provided:  a) 1001 South 17th Street, Philadelphia, PA - The employees were working in an excavation approximately 70 feet long by 70 feet wide and 10 feet deep in which the spoil pile and the Hitachi EX150 excavator was not placed or kept at least 2 feet from the entrance of the excavation nor were any retaining devices used. This condition exposed the employees to cave-in/struck-by hazards. This violation was observed on or about January 17, 2013.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
  • — Z (S) $3080

1926.652 A01

Serious Gravity 10 1 instance 5 exposed
Issued
Mar 21, 2014
Penalty
Initial $3,080 · Current $3,080
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system:  a) 1001 South 17th Street, Philadelphia, PA - The employees were working in a basement foundation excavation approximately 70 feet long by 70 feet wide and 10 feet deep in which the employees were not protected from cave-in hazards by a protective system. This violation was observed on or about January 17, 2013.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
  • — Z (S) $3080

View Real Construction, LLC's full OSHA safety record →