BOULDER, CO —
OSHA Inspection: AGR BUILDING INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of AGR BUILDING INC. in 1107 - 12TH STREET, BOULDER, CO 80302 (NAICS 236118). OSHA activity number 339588832.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AGR BUILDING INC.
- Site address
- 1107 - 12TH STREET
- City
- BOULDER
- State
- CO
- ZIP
- 80302
- Mailing
- 1035 PEARL STREET SUITE 205, BOULDER, CO 80302
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.405 A02 II C
- Issued
- Mar 3, 2014
- Abate by
- Mar 27, 2014
- Penalty
- Initial $1,760 · Current $880 Reduced
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(C): Each temporary wiring branch circuit not installed in a complete metallic raceway did not contain a separate equipment grounding conductor: (a)AGR Building Inc. at 1107 12th Street, Boulder, CO 80302: On and before February 13th, 2014, the controlling employer did not ensure that the receptacles used by the subcontractors, hanging down from the breaker panel on the west side of the building, contained separate grounding conductors. The condition exposed subcontractor employees to shock and electrocution hazards.
Recent events (2)
- — I (S) $880
- — Z (S) $1760
1926.405 E01
- Issued
- Mar 3, 2014
- Abate by
- Mar 27, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed so as to prevent moisture or water from entering and accumulating within the enclosures: (a)AGR Building Inc. at 1107 12th Street, Boulder, CO 80302: On and before February 13th, 2014, the controlling employer did not ensure that the breaker panel on the west side of the building, connected to the electrical meter and to conduit for temporary outlets, was installed so as to prevent moisture or water from entering and accumulating within the enclosure. The condition exposed subcontractor employees to shock and electrocution hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.405 F
- Issued
- Mar 3, 2014
- Abate by
- Mar 27, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(f): The conductor insulation used was not of the type suitable for the voltage, operating temperature, and location of use: (a)AGR Building Inc. at 1107 12th Street, Boulder, CO 80302: On and before February 13th, 2014, the controlling employer did not ensure that the conductor connected to the breaker panel on the west side of the building and running to an outlet box was insulated. The condition exposed subcontractor employees to shock and electrocution hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.405 J02 II
- Issued
- Mar 3, 2014
- Abate by
- Mar 27, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(j)(2)(ii): A receptacle installed in a wet location was not designed for the location: (a)AGR Building Inc. at 1107 12th Street, Boulder, CO 80302: On and before February 13th, 2014, the controlling employer did not ensure that the receptacles used by the subcontractors, hanging down from the breaker panel to the ground level on the west side of the building, was designed for this wet location, in that, the receptacles had no covers. The condition exposed subcontractor employees to shock and electrocution hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.652 A01
- Issued
- Mar 3, 2014
- Abate by
- Mar 27, 2014
- Penalty
- Initial $3,080 · Current $1,540 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) or (c): (a)AGR Building Inc. at 1107 12th Street, Boulder, CO 80302: On and before February 13th, 2014, the controlling employer did not ensure that the excavation was protected by an adequate protective system along the north wall (9 foot high vertical wall) and east wall (6 foot high with a slope greater than 66 degrees) in Type B soil. The condition exposed subcontractor employees to cave-in.
Recent events (2)
- — I (S) $1540
- — Z (S) $3080
1926.651 K01
- Issued
- Mar 3, 2014
- Abate by
- Mar 27, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems: (a)AGR Building Inc. at 1107 12th Street, Boulder, CO 80302: On and before February 13th 2014, the controlling employer did not ensure that a competent person inspected this excavation along the north and east walls prior to the start of work and as needed throughout the shift. The condition exposed employees to cave-in.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at AGR Building INC.
View AGR Building INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236118)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339588832.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.