Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AGR BUILDING, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AGR BUILDING, INC. in 1107 12TH STREET, BOULDER, CO 80302 (NAICS 236116). OSHA activity number 340151240.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AGR Building, INC. — free Get an email when a new federal OSHA severe-injury report for AGR Building, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
AGR BUILDING, INC.
Site address
1107 12TH STREET
City
BOULDER
State
CO
ZIP
80302
Mailing
1035 PEARL ST. SUITE 205, BOULDER, CO 80302
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
20
Ownership type
A

2 citations on file for this inspection.

1926.20 B02

Repeat Gravity 5 1 instance 1 exposed
Issued
Feb 24, 2015
Abate by
Mar 14, 2015
Penalty
Initial $5,280 · Current $3,168 Reduced
29 CFR 1926.20(b)(2): Such programs did not provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers (i.e. a person who is capable of identifying existing and predictable hazards in the surroundings or working conditions which are unsanitary, hazardous, or dangerous to employees, and who has the authority to take prompt corrective measures to eliminate them):    (a)AGR Building, Inc. @ 1107 12th Street, Boulder, CO 80302: On and before November 10th, 2014 the employer did not provide for frequent and regular inspections of the job sites, materials, and equipment to be made by a competent person.  Employees and subcontractor employees were using an elevated make-shift walk-way consisting of decking material and plywood to access and egress from a multi-family structure under construction. The walk-way did not have guardrails installed to ensure employees were protected from fall hazards. Employees and subcontractor employees were exposed to a fall hazard while crossing over the walk-way. The controlling employer did not maintain a safety program which included frequent and regular inspections of the jobsite. This condition exposed employees and subcontractor employees to a fall hazard of approximately 15 feet.    AGR Building, Inc. was previously cited for a violation of the same or substantially similar condition of this Occupational Safety and Health Administration Standard, 29 CFR 1926.20(b)(2), which was contained in OSHA Inspection number 938785, Citation number 1, Item 1 issued on October 25, 2013, and became Final Order on November 6, 2013, with respect to a workplace located at 932 Gapter Road, Boulder, CO 80303.
Recent events (2)
  • — I (R) $3168
  • — Z (R) $5280

1926.501 B01

Serious Gravity 10 1 instance 4 exposed
Issued
Feb 24, 2015
Abate by
Mar 14, 2015
Penalty
Initial $3,080 · Current $1,848 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:     (a)AGR Building, Inc. @ 1107 12th Street, Boulder, CO 80302: On and before November 10th, 2014, the employer did not ensure that each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level was protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  A make-shift walkway consisting of corrugated decking material and plywood was created to allow employees and subcontractor employees access and egress from a multi-family residential structure under construction. The walk way did not have guardrails to protect employees and subcontractor employees from a fall hazard into the foundation of the structure. This condition exposed employees to fall hazards of almost 15 feet.
Recent events (2)
  • — I (S) $1848
  • — Z (S) $3080

View AGR Building, INC.'s full OSHA safety record →