WOOD RIVER, IL ·
OSHA Inspection: WATCO COMPANIES, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of WATCO COMPANIES, LLC in 435 N OLD SAINT LOUIS RD, WOOD RIVER, IL 62095 (NAICS 336510). OSHA activity number 339601148.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WATCO COMPANIES, LLC
- Site address
- 435 N OLD SAINT LOUIS RD
- City
- WOOD RIVER
- State
- IL
- ZIP
- 62095
- Mailing
- 435 N OLD SAINT LOUIS RD, WOOD RIVER, IL 62095
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336510
- Employees
- 121
- Ownership type
- Private (A)
Citations
8 citations on file for this inspection.
1910.25 D02 I
- Issued
- Aug 18, 2014
- Abate by
- Sep 12, 2014
- Penalty
- Initial $2,700 · Current $2,700
General-duty citation text
Standard: 29 CFR 1910.25(d)(2)(i): The ladder shall be so placed as to prevent slipping, or it shall be lashed, or held in position: The six foot portable wood ladder used to access the base of the bucket elevator pit in the Pot Room Blast Area was placed vertically against the pit wall and was not secured to prevent slips or falls.
Recent events (3)
- · A (S) $2700
- · I (S) $1890
- · Z (S) $2700
1910.132 D01 I
- Issued
- Aug 18, 2014
- Abate by
- Oct 3, 2014
- Penalty
- Initial $4,500 · Current $4,500
General-duty citation text
29 CFR 1910.132(d)(1)(i): When the employer had assessed the workplace hazard(s) and determined that hazard(s) were present, the employer did not select and/or use the types of personal protective equipment that would protect the affected employee from the hazards: The employer did not select or require the use of suitable fall protection devices at all times in the following instances: a) Dome Building, employees accessing the top of the Hopper Car rail cars, were exposed to fall hazards of over 10 feet. b) Project Shop, employees accessing the second level of the Auto transport rail cars to weld were exposed to fall hazards over 9 feet high.
Recent events (3)
- · A (S) $4500
- · I (S) $3150
- · Z (S) $4500
1910.147 C04 II D
- Issued
- Aug 18, 2014
- Abate by
- Sep 12, 2014
- Penalty
- Initial $4,500 · Current $4,500
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control: The employer did not ensure that company's energy control procedures identified the specific steps for testing and verifying the hazardous energy sources were properly locked out. The deficient procedures include but are not limited to: a) ECP 005- ECP 014 b) ECP 005- ECP 015 c) ECP 005- ECP 016 d) ECP 005- ECP 017 e) ECP 005- ECP 020
Recent events (3)
- · A (S) $4500
- · I (S) $3150
- · Z (S) $4500
1910.147 C06 I
- Issued
- Aug 18, 2014
- Abate by
- Oct 3, 2014
- Penalty
- Initial $4,500 · Current $4,500
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: An annual/periodic inspection of the energy control procedures has not been conducted for, but not limited to the Blast System, Paint Kitchen, Paint Heaters, Bryant Heating Unit , Furnace and Air Conditioner to Painters Shower Room.
Recent events (3)
- · A (S) $4500
- · I (S) $3150
- · Z (S) $4500
1910.147 D04 I
- Issued
- Aug 18, 2014
- Abate by
- Oct 3, 2014
- Penalty
- Initial $4,500 · Current $4,500
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: On or about February 19, 2014, in the Blast Department, the system was not locked out when an employee was injured when attempting repairs in the Pot Room.
Recent events (3)
- · A (S) $4500
- · I (S) $3150
- · Z (S) $4500
1910.147 C07 I
- Issued
- Aug 18, 2014
- Abate by
- Oct 3, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices: Throughout the facility employees received ineffective training to ensure they understood the purpose and function of the lockout program and that they acquired the knowledge and skills required for safe application, usage and removal of energy controls, exposing employees to the unexpected release of hazardous energy sources.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.304 G05
- Issued
- Aug 18, 2014
- Abate by
- Aug 22, 2014
- Penalty
- Initial $3,600 · Current $3,600
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: Blast Department, on the Lasko Pedestal Fan, the 110 volt flexible cord was missing its electrical grounding pin in the plug. Employees were exposed to an electrical shock hazards.
Recent events (3)
- · A (S) $3600
- · I (S) $2520
- · Z (S) $3600
1910.305 G02 III
- Issued
- Aug 18, 2014
- Abate by
- Aug 22, 2014
- Penalty
- Initial $3,600 · Current $3,600
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) Blast Department: On the 110 volt Dayton Pedestal fan, the outer insulation was pulled out of its end electrical plug on the flexible cord, allowing strain to be placed on the inner electrical connections. Employees were exposed to an electrical shock hazards. b) Blast Department: On the Miller MIG welder, 440 volts, the outer insulation was pulled out of if its end electrical plug on the flexible core, allowing strain to be placed on the inner electrical connections. Employees were exposed to an electrical shock hazards.
Recent events (3)
- · A (S) $3600
- · I (S) $2520
- · Z (S) $3600
More inspections at Watco Companies, LLC
View Watco Companies, LLC's full OSHA safety record →
More inspections in this industry (NAICS 336510)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339601148.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.