Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: FEATHER FALLS CASINO - MOORETOWN RANCHERIA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FEATHER FALLS CASINO - MOORETOWN RANCHERIA in 3 ALVEDRA DRIVE DIRECTOR OF SECURITY, OROVILLE, CA 95966 (NAICS 713290). OSHA activity number 339609695.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Feather Falls Casino - Mooretown Rancheria for free Get an email when a new federal OSHA severe-injury report for Feather Falls Casino - Mooretown Rancheria is published. One employer, no account, unsubscribe in one click.
Site address
3 ALVEDRA DRIVE DIRECTOR OF SECURITY
City
OROVILLE
State
CA
ZIP
95966
Mailing
3 ALVEDRA DRIVE, OROVILLE, CA 95966
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
713290
Employees
500
Ownership type
Private (A)

7 citations on file for this inspection.

1910.333 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 14, 2014
Abate by
May 8, 2014
Penalty
Initial $6,000 · Current $4,500 Reduced
29 CFR 1910.333(a)(1): Live parts to which an employee was exposed were not de-energized before the employee worked on or near them:   Establishment: On March 4, 2014, and at times prior thereto, employees performed trouble-shooting and live electrical work up to 208 volts on electrical equipment like ballasts on the casino floor.
Recent events (2)
  • · I (S) $4500
  • · Z (S) $6000

1910.335 A01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 14, 2014
Abate by
May 8, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed:   Establishment: On March 4, 2014, and at times prior thereto, adequate electrical personal protective equipment such as, but not limited to, fire resistant clothing, volt rated gloves, hard hats, and safety glasses were not provided to employees who worked performed trouble-shooting and live electrical work up to 208 volts.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.22 D01

Other-than-serious 1 instance 5 exposed
Issued
Apr 14, 2014
Abate by
Apr 18, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate:   Maintenance Shop: On March 4, 2014, and at times prior thereto, employees work near and under the storage mezzanine above maintenance offices which was not rated for load capacity.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.132 D02

Other-than-serious 1 instance 400 exposed
Issued
Apr 14, 2014
Abate by
Apr 18, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, the identity of the workplace evaluated, the person certifying that the evaluation had been performed, and the date the hazard assessment was done:   Establishment: On March 4, 2014, and at times prior thereto, the employer did not certify a Personal Protective Equipment Hazard Assessment  that identified what employees wear when performing a specific job task.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.213 B03

Other-than-serious 1 instance 1 exposed
Issued
Apr 14, 2014
Abate by
May 8, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.213(b)(3): Provisions were not made to prevent woodworking machine(s) from automatically restarting upon restoration of power after power failure:   Maintenance Shop: On March 4, 2014, and at times prior thereto, the JET Gold Series table saw, model JTAS10-1, was not provided with anti-restart control thus exposing employees to lacerations and amputations.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.253 B02 II

Other-than-serious 1 instance 5 exposed
Issued
Apr 14, 2014
Abate by
Apr 18, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons:   Maintenance Shop: On March 4, 2014, and at times prior thereto, employees worked next to one argon and one acetylene cylinder that were not properly secured and could be subject to being knocked over or damaged.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.303 E01 I

Other-than-serious 1 instance 5 exposed
Issued
Apr 14, 2014
Abate by
May 8, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.303(e)(1)(i): The manufacturer's name, trademark, or other descriptive marking by which the organization responsible for the product was not identified on the electrical equipment:  Maintenance Shop, Work Bench: On March 4, 2014, and at times prior thereto, employees used an in-house made piece of electrical equipment which consisted of a four-plug outlet box and an extension cord ran permanently from it to another four-plug outlet box. There was no label on the outlet boxes with the manufacturer's name, current, or wattage.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Feather Falls Casino - Mooretown Rancheria's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339609695.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.