CHICAGO, IL —
OSHA Inspection: GRANE TRANSPORTATION INDUSTRIES, INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of GRANE TRANSPORTATION INDUSTRIES, INC in 1011 S. LARAMIE, CHICAGO, IL 60644 (NAICS 484121). OSHA activity number 339633919.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GRANE TRANSPORTATION INDUSTRIES, INC
- Site address
- 1011 S. LARAMIE
- City
- CHICAGO
- State
- IL
- ZIP
- 60644
- Mailing
- 1011 S. LARAMIE, CHICAGO, IL 60644
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 484121
- Employees
- 395
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.215 A04
- Issued
- Apr 24, 2014
- Abate by
- Jun 11, 2014
- Penalty
- Initial $4,000 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rests. On offhand grinding machines, work rests shall be used to support the work. They shall be of rigid construction and designed to be adjustable to compensate for wheel wear. Work rests shall be kept adjusted closely to the wheel with a maximum opening of one-eighth inch to prevent the work from being jammed between the wheel and the rest, which may cause wheel breakage. The work rest shall be securely clamped after each adjustment. The adjustment shall not be made with the wheel in motion. Maintenance shop area- On or about March 17, 2014, the distance betwen the abrasive wheel and the adjustable work rest on the Dayton industrial grinder, manufacturer's serial number IZ707Y, exceeded one-eighth inch, thereby exposing employees to struck-by hazard(s) associated with rotating abrasive wheel and wheel breakage.
Recent events (2)
- — I (S) $2000
- — Z (S) $4000
1910.215 B09
- Issued
- Apr 24, 2014
- Abate by
- Jun 11, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): Exposure adjustment. Safety guards of the types described in Subparagraphs (3) and (4) of this paragraph, where the operator stands in front of the opening, shall be constructed so that the peripheral protecting member can be adjusted to the constantly decreasing diameter of the wheel. The maximum angular exposure above the horizontal plane of the wheel spindle as specified in paragraphs (b)(3) and (4) of this section shall never be exceeded, and the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top shall never exceed one-fourth inch. (See Figures O-18, O-19, O-20, O-21, O-22, and O-23.) Maintenance shop area- On or about March 17, 2014, Dayton industrial pedestal grinder, manufacturer's serial number 1Z707Y, did not have a tongue guard on the right side of grinding wheel, thereby exposing employees to struck-by hazard(s) from flying particles.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.244 A01 I
- Issued
- Apr 24, 2014
- Abate by
- Jun 11, 2014
- Penalty
- Initial $4,000 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.244(a)(1)(i): The operator shall make sure that the jack used has a rating sufficient to lift and sustain the load. Maimtenance shop area- On or about March 17, 2014, The operator did not ensure the jack stand capacity rating was legible.
Recent events (2)
- — I (S) $2000
- — Z (S) $4000
1910.244 A02 VIII
- Issued
- Apr 24, 2014
- Abate by
- Jun 11, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.244(a)(2)(viii): Jacks which are out of order shall be tagged accordingly, and shall not be used until repairs are made. Maintenance shop area- On or about March 17, 2014, Employees were required to use jackstands that were either unserviceable and/or in need of repair. Thereby exposing employees to struck-by and caught between hazard(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B02
- Issued
- Apr 24, 2014
- Abate by
- Jun 11, 2014
- Penalty
- Initial $4,000 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling. Maintenance shop area- On or about March 17, 2014, employees were required to use a metal knockout type outlet box that was not wall mounted. The outlet box was being used as a 10 foot extension cord that was then plugged into a nearby wall mounted outlet. Thereby exposing employees to shock, electrocution, and fire hazard(s).
Recent events (2)
- — I (S) $2000
- — Z (S) $4000
1910.304 A02
- Issued
- Apr 24, 2014
- Abate by
- Jun 11, 2014
- Penalty
- Initial $4,000 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.304(a)(2): Polarity of connections. No grounded conductor may be attached to any terminal or lead so as to reverse designated polarity. Maintenance shop, south wall- On or about March 17, 2014, employees were required to use a four gang wall outlet box that provided energy to a variety of portable shop tools and equipment with open ground polarity. Thereby exposing employees to shock, electrocution, and fire hazard(s).
Recent events (2)
- — I (S) $2000
- — Z (S) $4000
1910.304 B02 II
- Issued
- Apr 24, 2014
- Abate by
- Jun 11, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(b)(2)(ii): Receptacles and cord connectors having grounding contacts shall have those contacts effectively grounded. Maintenance shop area, south wall- On or about March 17, 2014, employees were required to use dual wall outlets that had broken ground pins lodged inside of them. Thereby exposing employees to shock and electrocution hazard(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01
- Issued
- Apr 24, 2014
- Abate by
- Jun 11, 2014
- Penalty
- Initial $4,000 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.305(b)(1): Conductors entering boxes, cabinets, or fittings. Maintenance shop area- On or about March 17, 2014, employer did not ensure energized wires entering the top and bottom of control boxes were protected from damage and abrasion. The openings were not effectively closed. Thereby exposing employees to shock and electrocution hazard(s).
Recent events (2)
- — I (S) $2000
- — Z (S) $4000
1910.305 B01 I
- Issued
- Apr 24, 2014
- Abate by
- Jun 11, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. Maintenance shop area, south wall- On or about March 17, 2014, employees were required to use a wall switch with exposed live wires. Thereby exposing employees to shock and electrocution hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G02 II
- Issued
- Apr 24, 2014
- Abate by
- Jun 11, 2014
- Penalty
- Initial $4,000 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords may be used only in continuous lengths without splice or tap. Hard-service cord and junior hard-service cord No. 14 and larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced. Maintenance shop area and throughout facility- On or about March 17, 2014, employees were required to use Dyna-Glo pro portable electric heaters with 10 foot power cord(s) that had been spliced twice along their entire length. Exposed conductors could be visibly seen after black electrical tape was removed. Thereby exposing employees to shock and electrocution hazard.
Recent events (2)
- — I (S) $2000
- — Z (S) $4000
1910.334 A02 I
- Issued
- Apr 24, 2014
- Abate by
- Jun 11, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) shall be visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket). Cord and plug connected equipment and flexible cord sets (extension cords) which remain connected once they are put in place and are not exposed to damage need not be visually inspected until they are relocated. Steel blue tool cabinet number five (5)- On or about March 17, 2014, employees were required to use cord and plug equipment including, but not limited to power drill equipment, on a daily basis. The insulation on the electrical cord for the power drill was visibly damaged and was covered with black electrical tape. Thereby exposing employees to shock and electrocution hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Grane Transportation Industries, INC
View Grane Transportation Industries, INC's full OSHA safety record →
More inspections in this industry (NAICS 484121)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339633919.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.