Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JR ROOFING, LTD.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JR ROOFING, LTD. in 462 ORCHARD, WINNETKA, IL 60093 (NAICS 238160). OSHA activity number 339656837.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch JR Roofing, LTD. — free Get an email when a new federal OSHA severe-injury report for JR Roofing, LTD. is published. One employer, no account, unsubscribe in one click.
Establishment
JR ROOFING, LTD.
Site address
462 ORCHARD
City
WINNETKA
State
IL
ZIP
60093
Mailing
33 LEBARON STREET C, WAUKEGAN, IL 60085
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

4 citations on file for this inspection.

1926.502 D06 I

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 9, 2014
Abate by
Apr 15, 2014
Penalty
Initial $3,080 · Current $3,080
29 CFR 1926.502(d)(6)(i): Snap hooks were engaged directly to webbing, rope or wire rope when not designed for such connections:       a) A snaphook used as part of a personal fall arrest system was engaged directly to a lanyard when not designed for such connection.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — A (S) $3080
  • — I (S) $1540
  • — Z (S) $3080

1926.502 D15

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 9, 2014
Abate by
Apr 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person:    a) Fall protection was anchored to a sheet metal roof jack that was not designed to be used for the connection of personal fall protection or to support at least 5,000 pounds of force.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — A (S) $0
  • — I (S) $0
  • — Z (S) $0

1926.502 D16 III

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 9, 2014
Abate by
Apr 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level:        a) Employees were exposed to the hazard of free falling more than 6 feet and contacting lower level areas while using personal fall arrest systems that were not rigged to prevent these hazards.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — A (S) $0
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Repeat Gravity 10 1 instance 1 exposed
Issued
Apr 9, 2014
Abate by
Apr 15, 2014
Penalty
Initial $15,400 · Current $15,400
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):        a) Employees were exposed to the hazard of falling while working from a roof surface without the use of fall protection.     JR Roofing, LTD was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501 (b)(13) which was contained in OSHA inspection number 906746, citation 1, item 1, and was affirmed as a final order on July 18, 2013, with respect to a worksite located at 707 William, River Forest, Illinois.     JR Roofing, LTD was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501 (b)(13) which was contained in OSHA inspection number 314174038, citation 2, item 1, and was affirmed as a final order on April 14, 2010, with respect to a worksite located at 1161 Spruce Street, Winnetka, Illinois.       In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — A (R) $15400
  • — I (R) $7700
  • — Z (R) $15400

View JR Roofing, LTD.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339656837.