Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMPHENOL CORPORATION

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of AMPHENOL CORPORATION in 40-60 DELAWARE AVENUE, SIDNEY, NY 13838 (NAICS 334417). OSHA activity number 339662546.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Amphenol Corporation — free Get an email when a new federal OSHA severe-injury report for Amphenol Corporation is published. One employer, no account, unsubscribe in one click.
Site address
40-60 DELAWARE AVENUE
City
SIDNEY
State
NY
ZIP
13838
Mailing
40-60 DELAWARE AVENUE, SIDNEY, NY 13838
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334417
Employees
800
Ownership type
A

5 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 2 exposed
Issued
May 30, 2014
Penalty
Initial $3,400 · Current $2,380 Reduced
29 CFR 1910.23(c)(1): Open sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides:     a) Mezzanine Above Guage Inspection, on or about 4/8/14: Work platform was not guarded by a standard railing along the open side exposing employees to a 12 foot fall hazard.
Recent events (2)
  • — I (S) $2380
  • — Z (S) $3400

1910.212 A01

Serious Gravity 1 1 instance 1 exposed
Issued
May 30, 2014
Penalty
Initial $2,550 · Current $1,785 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created point of operation, rotating parts, and flying chips:         a) Electrical Maintenance Room for Department 52, on or about 4/8/14: Wilton Drill Press was not provided with a chuck and tool guard.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2550

1910.219 D01

Serious Gravity 1 1 instance 2 exposed
Issued
May 30, 2014
Penalty
Initial $2,550 · Current $1,785 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  a)  Tumbler Area, on or about 4/8/14:  The Shaker Table was not provided with a guard over the in-running nip points of the belt and pulley drive.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2550

1910.219 E01 I

Serious Gravity 1 1 instance 2 exposed
Issued
May 30, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o):   a)  Tumbler Area, on or about 4/8/14:  The Shaker Table was not provided with a guard over the in-running nip points of the belt and pulley drive.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 3 instances 3 exposed
Issued
May 30, 2014
Penalty
Initial $2,550 · Current $1,785 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a) Electrical Maintenance Room for Department 53, on or about 4/8/14: : Employees using duplex metal outlet box connected to a flexible cord that was not in accordance with UL approval. Box is listed for permanent mounting only.  b) Tumbler Area, on or about 4/8/14: : Employees using duplex metal outlet box connected to a flexible cord that was not in accordance with UL approval. Box is listed for permanent mounting only.  c) Bechlar Area, on or about 4/8/14: : Employees using a quad metal outlet box and a duplex metal outlet box connected to flexible cords that were not in accordance with UL approval. Boxes are listed for permanent mounting only.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2550

View Amphenol Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339662546.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.