JANESVILLE, WI —
OSHA Inspection: AMPHENOL CORPORATION
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of AMPHENOL CORPORATION in 3200 PALMER DR., JANESVILLE, WI 53545 (NAICS 334519). OSHA activity number 346321086.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMPHENOL CORPORATION
- Site address
- 3200 PALMER DR.
- City
- JANESVILLE
- State
- WI
- ZIP
- 53545
- Mailing
- 3200 PALMER DR., JANESVILLE, WI 53545
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334519
- Employees
- 318
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A03 II
- Issued
- Dec 16, 2022
- Abate by
- Jan 10, 2023
- Penalty
- Initial $14,502 · Current $9,245 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii):Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle: (a) On or about September 22, 2022, point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle while operating a PM-1440E-LB - Lathe to tap threads in PACCAR nuts in the Heater Module Maintenance Area. (b) On or about November 1, 2022, point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle while operating the Precision Mathews Drill Press-Model: PM-935TV located in the Heater Module Maintenance Area. (c) On or about November 2, 2022, point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle while operating the MasterForce Sander-Model: 240-0054 located in the Machine Shop Area. (d) On or about October 24, 2022, point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle while operating the Jet Milling/Drilling Machine-Model: JMD-18 located in the Machine Shop Area. (e) On or about October 3, 2022, point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle while operating the Craftsmen Drill Press-Model: 34984 located in the Machine Shop Area. (f) On or about October 19, 2022, point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle while operating the Jet Horizontal/Vertical Bandsaw-Model: HVBS-7MW located in the Machine Shop Area.
Recent events (2)
- — I (S) $9245
- — Z (S) $14502
1910.253 B02 IV
- Issued
- Dec 16, 2022
- Abate by
- Jan 10, 2023
- Penalty
- Initial $10,360 · Current $5,283 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(iv):Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use: On or about November 2, 2022, the employer did not ensure the cap was installed on a compressed gas cylinder (marked as containing Argon) that accepted a cap, and was not in use or connected for use, in the Heater Module Maintenance Shop.
Recent events (2)
- — I (S) $5283
- — Z (S) $10360
1910.253 B02 II
- Issued
- Dec 16, 2022
- Abate by
- Jan 3, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces were not located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. On or about November 2, 2022, the employer did not ensure compressed gas cylinders (marked as containing Argon) were stored in a location where they would not be knocked over by passing objects in the Heater Module Maintenance Shop.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Amphenol Corporation
View Amphenol Corporation's full OSHA safety record →
More inspections in this industry (NAICS 334519)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346321086.