Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BRANDKAMP INDUSTRIES INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BRANDKAMP INDUSTRIES INC. in 1012 INDUSTRIAL PARK DR., MONTGOMERY CITY, MO 63361 (NAICS 337110). OSHA activity number 339677452.

Watch Brandkamp Industries INC. — free Get an email when a new federal OSHA severe-injury report for Brandkamp Industries INC. is published. One employer, no account, unsubscribe in one click.
Site address
1012 INDUSTRIAL PARK DR.
City
MONTGOMERY CITY
State
MO
ZIP
63361
Mailing
1012 INDUSTRIAL PARK DR., MONTGOMERY CITY, MO 63361
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
20
Ownership type
A

5 citations on file for this inspection.

1910.305 G01 IV A

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $714.00 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a.  A power tool was plugged into an extension cord which was plugged into another extension cord with a missing ground pin which was left plugged in and used as a substitute for an outlet receptacle (overuse of extension cords).  Abatement documentation is required for this violation.
Recent events (2)
  • — I (S) $714
  • — Z (S) $1020

1910.305 G02 III

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  a.  Examples existed of damaged power cords and extension cords where there was insulation damage at the plug (no strain relief), such as with a jig saw, extension cord used to power the jig saw, and a belt sander.  Abatement documentation is required for this violation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  a.  An extension cord with a missing ground pin was used to power a hand tool; there was no visual inspection to ensure that electrically powered equipment and cords were not damaged before use.  (Note: according to the standard visual inspection is not required when equipment is left in place where there has been no change to the equipment, however, before its use the equipment must be inspected to ensure it is not damaged.)  Abatement documentation is required for this violation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Serious Gravity 1 1 instance 17 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $714.00 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a.  An annual inspection of the lockout program was not made and documented, including inspection of written specific procedures, ensuring that employees have been trained and only authorized employees are performing lockout (except for cord and plug machines where the machine is unplugged before servicing and the plug is within site of the employee), and lockout is conducted according to the requirements of the standard, such as placing a lock on the designated energy isolating device and subsequent applicable testing of the machine to ensure it is locked out.  (Note: lockout is not to be confused with machine guarding, and where guarding is adjusted correctly so that exposure is controlled according to the design of the guard.)  Abatement documentation is required for this violation.
Recent events (2)
  • — I (S) $714
  • — Z (S) $1020

1910.147 C04 II

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section:  a.  Specific lockout procedures were not in writing according to the standard requirements (see 1910.147(c)(4)(ii)(A) - (D)), which included the specific type of energy (such as electrical, air and the quantity, such as amount of voltage and pressure), shut down procedures, where to place the lock and which energy isolating device to use, and the specific method to test the machine to ensure energy has been isolated.  Abatement documentation is required for this violation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View BRANDKAMP INDUSTRIES INC.'s full OSHA safety record →