GREENWOOD VILLAGE, CO —
OSHA Inspection: APEX PLUMBING INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of APEX PLUMBING INC. in 5181 S. PENNSYLVANIA ST., GREENWOOD VILLAGE, CO 80121 (NAICS 238220). OSHA activity number 339702300.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- APEX PLUMBING INC.
- Site address
- 5181 S. PENNSYLVANIA ST.
- City
- GREENWOOD VILLAGE
- State
- CO
- ZIP
- 80121
- Mailing
- 12275 W. 48TH AVE, WHEAT RIDGE, CO 80033
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 30
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.652 A01
- Issued
- Jun 13, 2014
- Abate by
- Jul 31, 2014
- Penalty
- Initial $19,250 · Current $7,000 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section: a) On or about April 18, 2014, Apex Plumbing Inc. did not ensure that each employee in an excavation was protected from cave-in hazards. The employer did not use an adequate protective system in accordance with OSHA 1926.652(c) standards. The employees were working in a trench in excess of 10 feet exposing employees to the following conditions: 1. The ends of the trenches in the road and in the yard area were unprotected in that no end shores or other means were used to protect these areas. 2. The vertical shores that were in use were placed a distances in excess of shoring requirements for horizontal spacing. Where only one shore was used in the trench located in the road while employees were working in the trench. This trench was measured in excess of 10 feet in length. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet"). Apex Plumbing, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.652(a)(1), which was contained in OSHA inspection number 313715278, citation number 2, item number 2 and was affirmed as a final order on January 5, 2010, with respect to a workplace located at 880 Welch Street, Lakewood, Co 80226. Apex Plumbing, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.652(a)(1), which was contained in OSHA inspection number 311905376, citation number 2, item number 1b and was affirmed as a final order on August 26, 2008, with respect to a workplace located at 1910 W. Arkansas Ave., Denver Co 80223.
Recent events (2)
- — I (S) $7000
- — Z (R) $19250
1926.652 C04 III
- Issued
- Jun 13, 2014
- Abate by
- Jul 31, 2014
- Penalty
- Initial $3,080 · Current $2,625 Reduced
General-duty citation text
29 CFR 1926.652(c)(4)(iii): At least one copy of the design shall be maintained at the jobsite during construction of the protective system. After that time, the design may be stored off the jobsite, but a copy of the design shall be made available to the Secretary upon request. (a) On or about April 18, 2014, the employer did not maintain a copy of the tabulated data at the jobsite for vertical shoring systems. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $2625
- — Z (S) $3080
1926.651 C02
- Issued
- Jun 13, 2014
- Abate by
- Jul 31, 2014
- Penalty
- Initial $3,080 · Current $3,080
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: (a) On or about April 18, 2014, employees did not have a safe means of egress due to not having a ladder placed inside the vertical trench walls. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $3080
- — Z (S) $3080
More inspections at Apex Plumbing INC.
View Apex Plumbing INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238220)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339702300.