Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KEYSTONE STEEL STRUCTURES, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KEYSTONE STEEL STRUCTURES, LLC in 4 LERCHEBNMILLER DRIVE, NORTHAMPTON, PA 18067 (NAICS 236116). OSHA activity number 339731705.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Keystone Steel Structures, LLC — free Get an email when a new federal OSHA severe-injury report for Keystone Steel Structures, LLC is published. One employer, no account, unsubscribe in one click.
Site address
4 LERCHEBNMILLER DRIVE
City
NORTHAMPTON
State
PA
ZIP
18067
Mailing
230 KING RD., HONEY BROOK, PA 19344
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
5
Ownership type
A

2 citations on file for this inspection.

1926.453 B02 V

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 31, 2014
Penalty
Initial $1,445 · Current $1,012 Reduced
29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift.    a) Roof of Northampton Firehouse addition- On or about April 8, 2014, employees were working from a vehicle mounted aerial lift, in excess of 19 feet above grade, without wear a body belt/personal fall arrest harnesses with an attached lanyards.
Recent events (2)
  • — I (S) $1011.5
  • — Z (S) $1445

1926.760 D02

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 31, 2014
Penalty
Initial $1,445 · Current $1,012 Reduced
29 CFR 1926.760(d)(2):     a) Roof of Northampton firehouse addition - on or about April 8, 2014, employees were engaged in steel erection work while attaching standing seam panels to a low slope roof, in excess of 19 feet above finished grade, without utilizing any means of fall protection.