NORTHAMPTON, PA —
OSHA Inspection: KEYSTONE STEEL STRUCTURES, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of KEYSTONE STEEL STRUCTURES, LLC in 4 LERCHEBNMILLER DRIVE, NORTHAMPTON, PA 18067 (NAICS 236116). OSHA activity number 339731705.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KEYSTONE STEEL STRUCTURES, LLC
- Site address
- 4 LERCHEBNMILLER DRIVE
- City
- NORTHAMPTON
- State
- PA
- ZIP
- 18067
- Mailing
- 230 KING RD., HONEY BROOK, PA 19344
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.453 B02 V
- Issued
- Jul 31, 2014
- Penalty
- Initial $1,445 · Current $1,012 Reduced
General-duty citation text
29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift. a) Roof of Northampton Firehouse addition- On or about April 8, 2014, employees were working from a vehicle mounted aerial lift, in excess of 19 feet above grade, without wear a body belt/personal fall arrest harnesses with an attached lanyards.
Recent events (2)
- — I (S) $1011.5
- — Z (S) $1445
1926.760 D02
- Issued
- Jul 31, 2014
- Penalty
- Initial $1,445 · Current $1,012 Reduced
General-duty citation text
29 CFR 1926.760(d)(2): a) Roof of Northampton firehouse addition - on or about April 8, 2014, employees were engaged in steel erection work while attaching standing seam panels to a low slope roof, in excess of 19 feet above finished grade, without utilizing any means of fall protection.
Recent events (2)
- — I (S) $1011.5
- — Z (S) $1445
More inspections at Keystone Steel Structures, LLC
View Keystone Steel Structures, LLC's full OSHA safety record →
More inspections in this industry (NAICS 236116)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339731705.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.