Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GP ROOFING & CONSTRUCTION, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GP ROOFING & CONSTRUCTION, LLC in 104 BLUE SAGE ROAD LOT 19, PANAMA CITY BEACH, FL 32408 (NAICS 238160). OSHA activity number 339759201.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch GP Roofing & Construction, LLC — free Get an email when a new federal OSHA severe-injury report for GP Roofing & Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
104 BLUE SAGE ROAD LOT 19
City
PANAMA CITY BEACH
State
FL
ZIP
32408
Mailing
ONE HARGROVE GRADE SUITE 1-D, PALM COAST, FL 32137
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.1053 B05 I

Serious Gravity 10 1 instance 4 exposed
Issued
Sep 23, 2014
Penalty
Initial $7,000 · Current $7,000
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support):  a. On or about May 6, 2014, front of the home, employees are using a 24-foot extension ladder to gain access and egress from the roof area.  The ladder is not extended the 4:1 ratio as required, exposing the employees to fall hazards.  Pursuant to CFR 1903.9, the employer must submit documents describing the steps it is taking to ensure compliance, including an explanation of how these steps protect its employees from falls.  (An abatement plan and periodic progress reports may also be required if the abatement period is more than 90 days).
Recent events (1)
  • — Z (S) $7000

1926.501 B13

Willful Gravity 10 1 instance 4 exposed
Issued
Sep 23, 2014
Penalty
Initial $70,000 · Current $70,000
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a. On or about May 6, 2014, employees, installing roofing shingles and moving roofing materials on a 7:12 pitch residential roof, are not protected from falling 9 feet 1-inch by the use of a guardrail system, safety net system, personal fall arrest system or any other type of fall protection method.  Pursuant to CFR 1903.9, the employer must submit documents describing the steps it is taking to ensure compliance, including an explanation of how these steps protect its employees from falls.  (An abatement plan and periodic progress reports may also be required if the abatement period is more than 90 days).
Recent events (1)
  • — Z (W) $70000

1926.102 A01

Repeat Gravity 5 1 instance 4 exposed
Issued
Sep 23, 2014
Penalty
Initial $27,500 · Current $27,500
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:  a. On or about May 6, 2014, employees using Hitachi nail guns are not wearing eye protection, exposing themselves to eye injuries.  The GP Roofing & Construction, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.102(a)(1), which was contained in OSHA inspection number 315484881, Repeat citation number 01, item number 001 and was affirmed as a final order on April 27, 2012, with respect to a workplace located at 78012 Timber Creek Blvd. Yulee, Florida.  The GP Roofing & Construction, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.102(a)(1), which was contained in OSHA inspection number 315479659, Serious citation number 01, item number 001 and was affirmed as a final order on October 19, 2011, with respect to a workplace located at 499 Glendale Lane, Orange Park, Florida.  The GP Roofing & Construction, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.102(a)(1), which was contained in OSHA inspection number 315479899, Serious citation number 01, item number 001 and was affirmed as a final order on October 24, 2011, with respect to a workplace located at 460 Glendale Lane, Orange Park, Florida.  Pursuant to CFR 1903.9, the employer must submit documents describing the steps it is taking to ensure compliance, including an explanation of how these steps protect its employees from eye injuries.  (An abatement plan and periodic progress reports may also be required if the abatement period is more than 90 days).
Recent events (1)
  • — Z (R) $27500

1926.1053 B01

Repeat Gravity 10 1 instance 4 exposed
Issued
Sep 23, 2014
Penalty
Initial $38,500 · Current $38,500
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a. On or about May 6, 2014, the ladder placed at the front of the home is not extended 3 feet past the landing.  The GP Roofing & Construction, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.1053(b)(1), which was contained in OSHA inspection number 315484071, Repeat citation number 01, item number 002 and was affirmed as a final order on May 3, 2012, with respect to a workplace located at 13668 Chipperfield Lane, Jacksonville, Florida.  The GP Roofing & Construction, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.1053(b)(1), which was contained in OSHA inspection number 315478362, Serious citation number 01, item number 002 and was affirmed as a final order on September 26, 2011, with respect to a workplace located at 322 Willow Winds Parkway, Jacksonville, Florida.  The GP Roofing & Construction, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.1053(b)(1), which was contained in OSHA inspection number 315636019, Serious citation number 01, item number 002 and was affirmed as a final order on September 6, 2011, with respect to a workplace located at 1234 Canyon Oaks, Brandon, Florida.  Pursuant to CFR 1903.9, the employer must submit documents describing the steps it is taking to ensure compliance, including an explanation of how these steps protect its employees from falls.  (An abatement plan and periodic progress reports may also be required if the abatement period is more than 90 days).
Recent events (1)
  • — Z (R) $38500

View GP Roofing & Construction, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339759201.