OSHA Inspection: FORUM ENERGY TECHNOLOGIES

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of FORUM ENERGY TECHNOLOGIES in 2005 GARDEN ROAD, PEARLAND, TX 77581 (NAICS 333132). OSHA activity number 339760142.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Forum Energy Technologies — free Get an email when a new federal OSHA severe-injury report for Forum Energy Technologies is published. One employer, no account, unsubscribe in one click.
Site address
2005 GARDEN ROAD
City
PEARLAND
State
TX
ZIP
77581
Mailing
2005 GARDEN ROAD, PEARLAND, TX 77581
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333132
Employees
300
Ownership type
A

5 citations on file for this inspection.

1910.95 C01

Serious Gravity 1 5 instances 5 exposed
Issued
Aug 18, 2014
Abate by
Sep 18, 2014
Penalty
Initial $2,550 · Current $1,530 Reduced
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equaled or exceeded an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:   a) In the Centralizer, a hearing conservation program had not been established.  A machine operator was exposed to 102.0% of the noise dose which is equivalent to approximately 90.1 dBA. Sampling was conducted for 391 minutes on June 17, 2014. Zero exposure was assumed for the remaining 209 minutes.   b) In the Centralizer, a hearing conservation program had not been established.  A machine operator was exposed to 99.36% of the noise dose which is equivalent to approximately 89.9 dBA. Sampling was conducted for 412 minutes on June 17, 2014. Zero exposure was assumed for the remaining 188 minutes.   c) In the Centralizer, a hearing conservation program had not been established.  A machine operator was exposed to 81.2% of the noise dose which is equivalent to approximately 88.4 dBA. Sampling was conducted for 403 minutes on June 17, 2014. Zero exposure was assumed for the remaining 197 minutes.   d) In the Centralizer, a hearing conservation program had not been established.  A machine operator was exposed to 74.2% of the noise dose which is equivalent to approximately 87.8 dBA. Sampling was conducted for 404 minutes on June 17, 2014. Zero exposure was assumed for the remaining 196 minutes.   e) In the Centralizer, a hearing conservation program had not been established.  A laborer was exposed to 68.82% of the noise dose which is equivalent to approximately 87.3 dBA. Sampling was conducted for 402 minutes on June 17, 2014. Zero exposure was assumed for the remaining 198 minutes.
Recent events (2)
  • — I (S) $1530
  • — Z (S) $2550

1910.303 F02

Serious Gravity 5 2 instances 3 exposed
Issued
Aug 18, 2014
Abate by
Aug 26, 2014
Penalty
Initial $3,400 · Current $2,040 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  (a) at the facility, to the right of the dip tanks in the phosphorous line, the disconnecting means for the exhaust fans was not labeled.  (b) at the facility, to the right of the dip tanks in the phosphorous line, the disconnecting means for the lifting device was not labeled.
Recent events (2)
  • — I (S) $2040
  • — Z (S) $3400

1910.305 B01 I

Serious Gravity 5 2 instances 1 exposed
Issued
Aug 18, 2014
Abate by
Aug 26, 2014
Penalty
Initial $4,250 · Current $2,550 Reduced
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions:  (a) at the facility, to the right of the phosphorous line, conductors going from the disconnecting means for the exhaust fan into the bottom of the on/off switch were not protected from abrasions.
Recent events (2)
  • — I (S) $2550
  • — Z (S) $4250

1910.1200 G08

Serious Gravity 1 3 instances 3 exposed
Issued
Aug 18, 2014
Abate by
Aug 26, 2014
Penalty
Initial $2,550 · Current $1,530 Reduced
29 CFR 1910.1200(g)(8):   The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work  shift to employees when they were in their work area(s):  (a)  at the facility on the phosphate line, a Safety Data Sheet (SDS) for Soluhib 5340, an irritant, was not readily accessible to employees in their work area.
Recent events (2)
  • — I (S) $1530
  • — Z (S) $2550

1910.1200 H01

Serious Gravity 1 3 instances 3 exposed
Issued
Aug 18, 2014
Abate by
Sep 18, 2014
Penalty
Initial $2,550 · Current $1,530 Reduced
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  (a)  at the facility on the phosphate line, employees were not informed of the requirements of 29 CFR 1910.1200; operations in their work area where hazardous chemicals were present; and the location and availability of the written hazard communication program , including the required lists of hazardous chemicals and the safety data sheets.  Employees were not trained on the methods and observations that may be used to detect the presence or release of a hazardous chemical in the work area; the physical and health hazards of chemicals in the work area; protective measures; and the details of the employer's hazard communication program, including how employees can obtain and use the appropriate hazard information.  Employees use hazardous substances such as, but not limited to, Solucoat 5047, a corrosive.
Recent events (2)
  • — I (S) $1530
  • — Z (S) $2550

View Forum Energy Technologies's full OSHA safety record →