MIDLAND, TX —
OSHA Inspection: FORUM ENERGY TECHNOLOGIES
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of FORUM ENERGY TECHNOLOGIES in 2216 E. CR 123, MIDLAND, TX 79706 (NAICS 332312). OSHA activity number 342762259.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FORUM ENERGY TECHNOLOGIES
- Site address
- 2216 E. CR 123
- City
- MIDLAND
- State
- TX
- ZIP
- 79706
- Mailing
- 2216 E. CR 123, MIDLAND, TX 79706
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 26
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.132 F02
- Issued
- Jan 5, 2018
- Abate by
- Feb 1, 2018
- Penalty
- Initial $12,675 · Current $8,873 Reduced
General-duty citation text
29 CFR 1910.132(f)(2): The employer did not require employees to demonstrate an understanding of the training specified in paragraph (f)(1) of this section, and the ability to use PPE properly, before being allowed to perform work requiring the use of PP On September 4, 2017 in the shop, employees engaged in putting a manifold truck together with the pipe joints 3 x 48, were exposed to caught between hazards.
Recent events (2)
- — I (S) $8872.5
- — Z (S) $12675
1904.39 A02
- Issued
- Jan 5, 2018
- Penalty
- Initial $9,959 · Current $0 Reduced
General-duty citation text
29 CFR 1904.39(a)(2): The employer failed to report the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, within (24) twenty-four hours. The employer failed to report an amputation that occurred on their site within a 24 hour period.
Recent events (2)
- — I (O) $0
- — Z (O) $9959
More inspections at Forum Energy Technologies
View Forum Energy Technologies's full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342762259.