Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PINNACLE CONSULTING, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PINNACLE CONSULTING, INC. in 41 NORWOOD STREET, BOSTON, MA 02122 (NAICS 238990). OSHA activity number 339777401.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pinnacle Consulting, INC. — free Get an email when a new federal OSHA severe-injury report for Pinnacle Consulting, INC. is published. One employer, no account, unsubscribe in one click.
Site address
41 NORWOOD STREET
City
BOSTON
State
MA
ZIP
02122
Mailing
4712 BECK LANE, RINGWOOD, IL 60072
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.451 E01

Serious Gravity 5 1 instance 5 exposed
Issued
Jun 17, 2014
Abate by
Jun 25, 2014
Penalty
Initial $4,200 · Current $4,200
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Jobsite: Second floor.  Employees were exposed to slips, trips, and falls while accessing/egressing the scissor lift platform where access/egress had not been provided and the crew was climbing over the platform guard rails.
Recent events (1)
  • — Z (S) $4200

1926.502 B09

Serious Gravity 1 1 instance 5 exposed
Issued
Jun 17, 2014
Abate by
Jun 25, 2014
Penalty
Initial $2,100 · Current $2,100
29 CFR 1926.502(b)(9): The employer failed to ensure that wire rope used as a top rail was flagged at 6-foot intervals with high-visibility material:  Jobsite: 2nd floor North, South, and West sides.  Employees were exposed to falls of approximately 16 feet to the ground below where approximately 350 feet of wire rope guard rail had not been flagged.
Recent events (1)
  • — Z (S) $2100

1926.501 B04 I

Serious Gravity 10 2 instances 5 exposed
Issued
Jun 17, 2014
Penalty
Initial $5,390 · Current $5,390
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes:  Jobsite: Southeast side of building, 2nd floor.  Employees were exposed to falling approximately 16 feet onto the concrete floor below through two (2) unguarded floor holes measuring approximately 4 feet by 8 feet.
Recent events (1)
  • — Z (S) $5390

1926.502 B04

Serious Gravity 5 48 instances 10 exposed
Issued
Jun 17, 2014
Penalty
Initial $3,850 · Current $3,850
29 CFR 1926.502(b)(4): Components used to construct the guardrail system had not been designed for the purpose:  Jobsite: North and West sides, 2nd floor.  Employees were exposed to falls of approximately 16 feet to the ground below while working/walking on the floor where one-hole, electrical metallic tubing (EMT) clips, which had not been so designed by the manufacturer, or tested and/or listed by an approved laboratory to be used as applied, were used to construct the wire rope perimeter guardrail system as fasteners at the columns.
Recent events (1)
  • — Z (S) $3850

1926.501 B01

Repeat Gravity 10 1 instance 5 exposed
Issued
Jun 17, 2014
Penalty
Initial $10,780 · Current $10,780
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:  Jobsite: West (Norwood Street) side of building, 2nd floor.  Employees were exposed to falls of approximately 16 feet onto the concrete floor below while working/walking in close proximity to a 4 feet gap in the decking that ran approximately 300 feet.   Pinnacle Consulting, Inc. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 1926.501(b)(1), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER  912114, CITATION NUMBER 1, ITEM 3, ISSUED ON 6/25/2013 WITH A FINAL ORDER DATE OF 7/18/2013.
Recent events (1)
  • — Z (R) $10780

View Pinnacle Consulting, INC.'s full OSHA safety record →