JACKSONVILLE, FL —
OSHA Inspection: RON RUSSELL ROOFING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RON RUSSELL ROOFING, INC. in 11158 RALEY CREEK RD. S, JACKSONVILLE, FL 32255 (NAICS 238160). OSHA activity number 339784704.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RON RUSSELL ROOFING, INC.
- Site address
- 11158 RALEY CREEK RD. S
- City
- JACKSONVILLE
- State
- FL
- ZIP
- 32255
- Mailing
- 4419 HUDNALL RD., JACKSONVILLE, FL 32207
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
1 citation on file for this inspection.
1926.501 B13
- Issued
- Jun 18, 2014
- Penalty
- Initial $7,000 · Current $4,200 Reduced
General-duty citation text
Ron Russell Roofing, Inc. was previously cited for a violation of this occupational safety and health standard (29 CFR 1926.501 (b)(13)), which was contained in OSHA inspection number 315481218, citation number 01, item number 001 and was affirmed as a final order on 12/16/2011, with respect to a workplace located at 13301 Currituck Drive, Jacksonville, FL. 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. On or about May 29, 2014, employees removing shingles and felt from the 9/12 pitch roof were not protected from a 8 feet 11 inch fall hazard by the use of conventional or alternative fall protection systems.
Recent events (2)
- — I (R) $4200
- — Z (R) $7000
More inspections at RON Russell Roofing, INC.