Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FLEXO CONVERTERS USA, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FLEXO CONVERTERS USA, INC. in 1200 NORTHROP ROAD, MERIDEN, CT 06450 (NAICS 322121). OSHA activity number 339836579.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Flexo Converters USA, INC. — free Get an email when a new federal OSHA severe-injury report for Flexo Converters USA, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1200 NORTHROP ROAD
City
MERIDEN
State
CT
ZIP
06450
Mailing
1200 NORTHROP ROAD, MERIDEN, CT 06450
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322121
Employees
65
Ownership type
A

3 citations on file for this inspection.

1910.22 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 14, 2014
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1910.22(b)(1): Aisles and passageways shall be kept clear and in good repairs with no obstructions across or in aisles that could create a hazard:   WORKSHOP:  The steel metal grates, placed on the floor between the passageway and the No. 3 Triumph machine in concrete area were creating a tripping hazard.     ABATED DURING THE INSPECTION.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1910.22 A02

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 14, 2014
Abate by
Oct 1, 2014
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1910.22(a)(2): The floor of every workroom shall be maintained in a clean and, so far as possible, a dry condition. Where wet processes are used, drainage shall be maintained, and false floors, platforms, mats, or other dry standing places should be provided where practicable.  WORKSHOP: The floor of the racking system between aisle ways #14 and #15 had an accumulation of water on the floor.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1910.178 P01

Other-than-serious 2 instances 3 exposed
Issued
Aug 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.178(p)(1): If at any time a powered industrial truck is found to be in need of repair, defective, or in any way unsafe, the truck shall be taken out of service until it has been restored to safe operating condition.  WORKSHOP: The back-up alarms/strobe lights on the following powered industrial trucks (PITs) were not operable:     1.  ACR Raymond reach; model 740R45IT, S/N 740-07-CB.   2.  Toyota PIT;  model 7FGou25, S/N 8327, 4500#s.       ABATED DURNG THE INSPECTION.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Flexo Converters USA, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339836579.