ST THOMAS, VI —
OSHA Inspection: CORAL WORLD OCEAN PARK
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CORAL WORLD OCEAN PARK in 6450 ESTATE SMITH BAY, ST THOMAS, VI 00802 (NAICS 713990). OSHA activity number 339840274.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CORAL WORLD OCEAN PARK
- Site address
- 6450 ESTATE SMITH BAY
- City
- ST THOMAS
- State
- VI
- ZIP
- 00802
- Mailing
- 6450 ESTATE SMITH BAY, ST THOMAS, VI 00802
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 713990
- Employees
- 70
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.22 B01
- Issued
- Nov 5, 2014
- Abate by
- Dec 3, 2014
- Penalty
- Initial $1,607 · Current $964 Reduced
General-duty citation text
29 CFR 1910.22(b)(1): Aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard. a. On or about 06/30/2014, Coral World Ocean Park - 6450 Estate Smith bay, St. Thomas, VI - Marine Garden exhibits back area -hallway: Employees are exposed to tripping hazards while using corridor which an obstruction across (uneven surface). NOTE: Certification and documentation of abatement must be submitted for this citation item as required by 29 CFR 1903.19(c) and (d), respectively
Recent events (2)
- — I (S) $964.2
- — Z (S) $1607
1910.303 G01 I
- Issued
- Nov 5, 2014
- Abate by
- Dec 3, 2014
- Penalty
- Initial $1,607 · Current $964 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(i): Work space was less than 30 inches wide in front of electric equipment operating at 600 volts, nominal, or less: Instance #1. On or about 06/30/2014, Coral World Ocean Park 6450 Estate Smith bay, St. Thomas, VI Generator House/electrical panel area: Access to electrical panels was blocked with supplies & equipment. Instance #2. On or about 06/30/2014, Coral World Ocean Park 6450 Estate Smith bay, St. Thomas, VI Marine Garden exhibits back-electrical panel area: Access to electrical panels was blocked with a sink. Note instances #1 &# 2: Certification and documentation of abatement must be submitted for this citation item as required by 29. CFR 1903.19(c) and (d), respectively.
Recent events (2)
- — I (S) $964.2
- — Z (S) $1607
1910.303 G02 I
- Issued
- Nov 5, 2014
- Abate by
- Dec 3, 2014
- Penalty
- Initial $2,678 · Current $1,607 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i):Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision: Instance #1. On or about 06/30/2014, Coral World Ocean Park 6450 Estate Smith bay, St. Thomas, VI Generator House/electrical panel area: Employees were using an electrical panels that have missing its dead front cover thus exposing breakers internal connections and bus bars, therefore, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact. Instance #2. On or about 06/30/2014, Coral World Ocean Park 6450 Estate Smith bay, St. Thomas, VI Main Kitchen / ice machine area: Employees were using an electrical ice machine where its compressor lid cover was missing, therefore, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact. Note: Certification and documentation of abatement must be submitted for this citation item as required by 29. CFR 1903.19(c) and (d), respectively.
Recent events (2)
- — I (S) $1606.8
- — Z (S) $2678
1910.305 B02 I
- Issued
- Nov 5, 2014
- Abate by
- Dec 3, 2014
- Penalty
- Initial $1,607 · Current $964 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: a. On or about 06/30/2014, Coral World Ocean Park 6450 Estate Smith bay, St. Thomas, VI - Marine Garden exhibits back area: Employees have been using electrical tools connected to an outlet box. The outlet box lacked a face plate cover. NOTE: Certification and documentation of abatement must be submitted for this citation item as required by 29 CFR 1903.19(c) and (d), respectively
Recent events (2)
- — I (S) $964.2
- — Z (S) $1607
More inspections at Coral World Ocean Park
View Coral World Ocean Park's full OSHA safety record →
More inspections in this industry (NAICS 713990)
More inspections in VI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339840274.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.