Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CORAL WORLD OCEAN PARK

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CORAL WORLD OCEAN PARK in 6450 ESTATE SMITH BAY, ST THOMAS, VI 00802 (NAICS 713990). OSHA activity number 339840274.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Coral World Ocean Park — free Get an email when a new federal OSHA severe-injury report for Coral World Ocean Park is published. One employer, no account, unsubscribe in one click.
Site address
6450 ESTATE SMITH BAY
City
ST THOMAS
State
VI
ZIP
00802
Mailing
6450 ESTATE SMITH BAY, ST THOMAS, VI 00802
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
713990
Employees
70
Ownership type
A

4 citations on file for this inspection.

1910.22 B01

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 5, 2014
Abate by
Dec 3, 2014
Penalty
Initial $1,607 · Current $964 Reduced
29 CFR 1910.22(b)(1): Aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard.    a.      On or about 06/30/2014, Coral World Ocean Park - 6450 Estate Smith bay, St. Thomas, VI - Marine Garden exhibits back area -hallway:   Employees are exposed to tripping hazards while using corridor which an obstruction across (uneven surface).     NOTE:   Certification and documentation of abatement must be submitted for this citation item as required by 29 CFR 1903.19(c) and (d), respectively
Recent events (2)
  • — I (S) $964.2
  • — Z (S) $1607

1910.303 G01 I

Serious Gravity 1 2 instances 2 exposed
Issued
Nov 5, 2014
Abate by
Dec 3, 2014
Penalty
Initial $1,607 · Current $964 Reduced
29 CFR 1910.303(g)(1)(i): Work space was less than 30 inches wide in front of electric equipment operating at 600 volts, nominal, or less:    Instance #1.  On or about 06/30/2014, Coral World Ocean Park  6450 Estate Smith bay, St. Thomas, VI Generator House/electrical panel area:  Access to electrical panels was blocked with supplies & equipment.      Instance #2.  On or about 06/30/2014, Coral World Ocean Park  6450 Estate Smith bay, St. Thomas, VI Marine Garden exhibits back-electrical panel area:  Access to electrical panels was blocked with a sink.      Note instances #1 &# 2: Certification and documentation of abatement must be submitted for this citation item as required by 29. CFR 1903.19(c) and (d), respectively.
Recent events (2)
  • — I (S) $964.2
  • — Z (S) $1607

1910.303 G02 I

Serious Gravity 5 2 instances 2 exposed
Issued
Nov 5, 2014
Abate by
Dec 3, 2014
Penalty
Initial $2,678 · Current $1,607 Reduced
29 CFR 1910.303(g)(2)(i):Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision:    Instance #1.  On or about 06/30/2014, Coral World Ocean Park  6450 Estate Smith bay, St. Thomas, VI Generator House/electrical panel area:  Employees were using an electrical panels that have missing its dead front cover thus exposing breakers internal connections and bus bars, therefore, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact.      Instance #2.  On or about 06/30/2014, Coral World Ocean Park  6450 Estate Smith bay, St. Thomas, VI Main Kitchen /  ice machine area:  Employees were using an electrical ice machine where its compressor lid cover was missing, therefore, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact.     Note:  Certification and documentation of abatement must be submitted for this citation item as required by 29. CFR 1903.19(c) and (d), respectively.
Recent events (2)
  • — I (S) $1606.8
  • — Z (S) $2678

1910.305 B02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 5, 2014
Abate by
Dec 3, 2014
Penalty
Initial $1,607 · Current $964 Reduced
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:    a.      On or about 06/30/2014, Coral World Ocean Park  6450 Estate Smith bay, St. Thomas, VI - Marine Garden exhibits back area:   Employees have been using electrical tools connected to an outlet box. The outlet box lacked a face plate cover.    NOTE:   Certification and documentation of abatement must be submitted for this citation item as required by 29 CFR 1903.19(c) and (d), respectively
Recent events (2)
  • — I (S) $964.2
  • — Z (S) $1607

View Coral World Ocean Park's full OSHA safety record →