Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CORAL WORLD OCEAN PARK

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CORAL WORLD OCEAN PARK in 6450 COKI POINT, ST THOMAS, VI 00802 (NAICS 713990). OSHA activity number 348424177.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Coral World Ocean Park — free Get an email when a new federal OSHA severe-injury report for Coral World Ocean Park is published. One employer, no account, unsubscribe in one click.
Site address
6450 COKI POINT
City
ST THOMAS
State
VI
ZIP
00802
Mailing
6450 COKI POINT, ST THOMAS, VI 00802
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
713990
Employees
90
Ownership type
A

4 citations on file for this inspection.

1910.151 C

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 29, 2026
Penalty
Initial $2,870 · Current $1,866 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use [ANSIZ358.1-2004]:   a. On or about August 7, 2025, outside the sea lions water tanks area.  An emergency eye wash station was not provided in the immediate area when employees used and/or handled corrosive products such as NSF sodium hypochlorite, 12.5% 55-gallon containers.    NOTE:   Certification of abatement is not required for this citation item as abatement was documented by the compliance safety and health officer prior to citation issuance.
Recent events (2)
  • — I (S) $1865.5
  • — Z (S) $2870

1910.303 G01

Other-than-serious 4 instances 6 exposed
Issued
Jan 29, 2026
Abate by
Feb 20, 2026
Penalty
Initial $632 · Current $411 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  On or about August 7, 2025, electrical service panels were not readily accessible in the following areas:  a. At the guest services/ticket booth area. A 3-drawer vertical metal file cabinet was placed in front and below one electrical panel.  b. At the Shark bar area.  A countertop was installed in front and below the electrical panel located next to the sink area.   c. At the Beach and bar cafe area. Two stainless-steel restaurant tables with kitchen appliances such as 12-cup Black and Decker coffee maker, a 3-liter hot water dispenser and a commercial countertop electric deep fryer were placed in front and below one electrical panel.   d. At the Dolphin gift shop storage room area. Several merchandise boxes were stored below electrical panel.  NOTE 1: Certification and documentation of abatement must be submitted for Instances a and b as required by 29 CFR 1903.19(c) and (d), respectively.   NOTE 2: Certification of abatement is not required for Instances c and d as abatement was documented by the compliance safety and health officer prior to citation issuance.
Recent events (2)
  • — I (O) $410.8
  • — Z (O) $632

1910.1200 E01

Other-than-serious 1 instance 1 exposed
Issued
Jan 29, 2026
Penalty
Initial $537 · Current $349 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  a. On or about August 7, 2025, outside the sea lions water tanks area. The employer did not develop a written hazard communication program to ensure safety data sheets availability when employees used and/or handled corrosive products such as NSF sodium hypochlorite, 12.5% 55-gallon containers.  NOTE:  Certification of abatement is not required for this citation item as abatement was documented by the compliance safety and health officer prior to citation issuance.
Recent events (2)
  • — I (O) $349.05
  • — Z (O) $537

1910.1200 G01

Other-than-serious 1 instance 1 exposed
Issued
Jan 29, 2026
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use:  a. On or about August 7, 2025, outside the sea lions water tanks area. The employer did not have a safety data sheet available when employees used and/or handled corrosive products such as NSF sodium hypochlorite, 12.5% 55-gallon containers.  NOTE: Certification of abatement is not required for this citation item as abatement was documented by the compliance safety and health officer prior to citation issuance.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Coral World Ocean Park's full OSHA safety record →