Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: RED WIND CASINO

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RED WIND CASINO in 12819 YELM HIGHWAY SE, OLYMPIA, WA 98513 (NAICS 713290). OSHA activity number 339853798.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch RED Wind Casino for free Get an email when a new federal OSHA severe-injury report for RED Wind Casino is published. One employer, no account, unsubscribe in one click.
Establishment
RED WIND CASINO
Site address
12819 YELM HIGHWAY SE
City
OLYMPIA
State
WA
ZIP
98513
Mailing
12819 YELM HIGHWAY SE, OLYMPIA, WA 98513
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
713290
Employees
550
Ownership type
Private (A)

4 citations on file for this inspection.

1910.215 B09

Serious Gravity 1 1 instance 5 exposed
Issued
Sep 15, 2014
Abate by
Oct 9, 2014
Penalty
Initial $2,295 · Current $2,295
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  (a) Maintenance shop Delta 8 inch bench grinder had one missing and one tongue guard out of adjustment.
Recent events (1)
  • · Z (S) $2295

1910.305 B01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 15, 2014
Abate by
Oct 9, 2014
Penalty
Initial $2,295 · Current $2,295
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  (a) Main electric phase room panel HV1A had missing breakers and no cover on the opening.
Recent events (1)
  • · Z (S) $2295

1910.305 G01 IV A

Other-than-serious 1 instance 10 exposed
Issued
Sep 15, 2014
Abate by
Oct 9, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  (a) Main kitchen area extension cord was run above the drop ceiling to power a permanently mounted bug zapper.
Recent events (1)
  • · Z (O) $0

1910.305 G01 IV B

Other-than-serious 1 instance 10 exposed
Issued
Sep 15, 2014
Abate by
Oct 9, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors:  (a) Near main Kitchen extension cord was run through a hole in the drop ceiling to power a permanently mounted bug zapper.
Recent events (1)
  • · Z (O) $0

View RED Wind Casino's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339853798.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.