Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SELLERS & SONS, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SELLERS & SONS, INC in SELLERS - BLDG #7, SELLS, AZ 85634 (NAICS 236118). OSHA activity number 339876906.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sellers & Sons, INC — free Get an email when a new federal OSHA severe-injury report for Sellers & Sons, INC is published. One employer, no account, unsubscribe in one click.
Establishment
SELLERS & SONS, INC
Site address
SELLERS - BLDG #7
City
SELLS
State
AZ
ZIP
85634
Mailing
2845 E. GANLEY RD, TUCSON, AZ 85706
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
6
Ownership type
A

2 citations on file for this inspection.

1926.404 B01 III C

Serious Gravity 1 1 instance 5 exposed
Issued
Nov 4, 2014
Abate by
Nov 24, 2014
Penalty
Initial $1,020 · Current $765 Reduced
29 CFR 1926.404(b)(1)(iii)(C): Each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, shall be visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage. Equipment found damaged or defective shall not be used until repaired.  Pisinemo Location #7:  On or about June 24, 2014 and at times prior thereto, employees were using extension cords with a missing grounding pin to operate the Mitre Saw and the Rigid compressor for pneumatic tools exposing operators to electrical hazards.
Recent events (2)
  • — I (S) $765
  • — Z (S) $1020

1926.405 B01

Serious Gravity 1 1 instance 3 exposed
Issued
Nov 4, 2014
Abate by
Nov 24, 2014
Penalty
Initial $1,020 · Current $765 Reduced
29 CFR 1926.405(b)(1): Unused openings in cabinets, boxes, and fittings were not effectively closed:  Pisinemo - Sellers # 7:  On or about June 24, 2014 and at times prior thereto, the outside electric panel box providing power to contractors  was not effectively closed.  The knockout at the bottom panel was missing. Employees were handling the panel to tape and provide overspray protection and were exposed to potential electrical hazards.