Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MIDWEST AIR TECHNOLOGIES, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of MIDWEST AIR TECHNOLOGIES, INC. in 605 EXPANSION BLVD, PORT WENTWORTH, GA 31407 (NAICS 332618). OSHA activity number 339883381.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Midwest AIR Technologies, INC. — free Get an email when a new federal OSHA severe-injury report for Midwest AIR Technologies, INC. is published. One employer, no account, unsubscribe in one click.
Site address
605 EXPANSION BLVD
City
PORT WENTWORTH
State
GA
ZIP
31407
Mailing
605 EXPANSION BLVD, PORT WENTWORTH, GA 31407
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332618
Employees
40
Ownership type
A

4 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 24, 2014
Abate by
Dec 19, 2014
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  a) At the Bergandi chain weaver #1, on or about July 31, 2014, and at times prior to, the wire benders were not adequately guarded in that the side of the rollers where the wire was fed into the machine did not have guards, exposing employees to a pinch point hazard.       b) At the Bergandi chain weaver #2, on or about July 31, 2014, and at times prior to, the wire benders were not adequately guarded in that the side of the rollers where the wire was fed into the machine did not have guards, exposing employees to a pinch point hazard.      c) At the Bergandi chain weaver #3, on or about July 31, 2014, and at times prior to, the wire benders were not adequately guarded in that the side of the rollers where the wire was fed into the machine did not have guards, exposing employees to a pinch point hazard.
Recent events (1)
  • — Z (S) $7000

1910.303 B07 IV

Serious Gravity 1 2 instances 2 exposed
Issued
Nov 24, 2014
Abate by
Jan 13, 2015
Penalty
Initial $2,805 · Current $2,805
29 CFR 1910.303(b)(7)(iv): Electrical equipment had damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating.      a) At the warehouse, on or about July 31, 2014, and at times prior to, an electrical box located on the top of an electric motor for a platform stretch wrapper was not closed adequately and the electrical wires were exposed, exposing employees to minor electrical shock hazards.      b) At the warehouse, on or about July 31, 2014, and at times prior to, the cover for an electric motor for a platform stretch wrapper was damaged and the electrical wires were exposed, exposing employees to minor electrical shock hazards.
Recent events (1)
  • — Z (S) $2805

1910.305 G01 IV A

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 24, 2014
Abate by
Jan 13, 2015
Penalty
Initial $2,805 · Current $2,805
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a) In the loading area, on or about July 31, 2014 and at times prior to, an extension cord was used in lieu of using fixed wiring of a structure to provide power for a radio, an industrial fan and a  platform stretch wrapper, resulting in an electrical hazard.
Recent events (1)
  • — Z (S) $2805

1910.305 G02 II

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 24, 2014
Abate by
Jan 13, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:  a) At the warehouse, on or about July 31, 2014, and at times prior to, the extension cord for the Infrapak Platform Stretch Wrapper located by the rack system had the electrical wires spliced together using black electrical tape, exposing employees to minor electrical shock hazards.
Recent events (1)
  • — Z (S) $0

View Midwest AIR Technologies, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339883381.