REVERE, MA —
OSHA Inspection: DELTA TYLER WATERPROOFING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DELTA TYLER WATERPROOFING, INC. in 1062 BROADWAY, REVERE, MA 02151 (NAICS 238160). OSHA activity number 339906844.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DELTA TYLER WATERPROOFING, INC.
- Site address
- 1062 BROADWAY
- City
- REVERE
- State
- MA
- ZIP
- 02151
- Mailing
- 936 WINTHROP AVENUE, REVERE, MA 02151
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
1 citation on file for this inspection.
1926.501 B10
- Issued
- Sep 19, 2014
- Abate by
- Oct 24, 2014
- Penalty
- Initial $6,160 · Current $3,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system. (a) Location - 1062 Broadway, Revere, MA: On or about 8/18/2014, employees working to install flashing on a roof greater than six foot above the lower level were not protected from falling. Delta Tyler Waterproofing, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(10), which was contained in OSHA inspection number 954990, citation number 1, item number 1 and was affirmed as a final order on 2/13/2014, with respect to a workplace located at 290 Westminster Street, Providence, RI 02903.
Recent events (2)
- — I (R) $3000
- — Z (R) $6160
More inspections at Delta Tyler Waterproofing, INC.
View Delta Tyler Waterproofing, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339906844.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.