GREAT BEND, KS —
OSHA Inspection: PRIMUS STERILIZER COMPANY INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PRIMUS STERILIZER COMPANY INC in 3707 N MAIN STREET, GREAT BEND, KS 67530 (NAICS 339113). OSHA activity number 339932899.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PRIMUS STERILIZER COMPANY INC
- Site address
- 3707 N MAIN STREET
- City
- GREAT BEND
- State
- KS
- ZIP
- 67530
- Mailing
- 3707 N MAIN STREET, GREAT BEND, KS 67530
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339113
- Employees
- 35
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.179 G01 V
- Issued
- Sep 12, 2014
- Penalty
- Initial $2,023 · Current $1,416 Reduced
General-duty citation text
29 CFR 1910.179(g)(1)(v): Pendant control box(es) were not clearly marked for identification of functions: In the welding shop - the pendant control for the south Branden Winch hoist being used as a bridge crane had only four of the 6 control buttons identified as to their use. Employees were exposed to the hazard of being struck-by the load being lifted.
Recent events (2)
- — I (S) $1416.1
- — Z (S) $2023
1910.303 B01
- Issued
- Sep 12, 2014
- Penalty
- Initial $1,517 · Current $1,062 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees, in that the employer did not ensure the safety of the equipment pursuant to the considerations in sections (i) through (viii) of 29 CR 1910.303(b)(1): In the far SW corner of the weld shop the electrical junction box cover would not shut due to the heavy gauge wires holding it open. Employees were exposed to a shock hazard.
Recent events (2)
- — I (S) $1061.9
- — Z (S) $1517
1910.303 G01
- Issued
- Sep 12, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment: a. The electrical panels behind the Press Brake in the Fab Shop were blocked by pieces of metal leaning against the panels/wall. Employees were exposed to a shock hazard. a. The electrical panel near the walk-thru exit door and green plastic trash can was blocked by the trash can and a large plastic pan setting on the floor. Employees were exposed to a shock hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- Sep 12, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a. In the SW corner of the weld shop a breaker was missing in the light brown breaker panel. Employees were exposed to a shock hazard. b. In the far SW corner of the weld shop the electrical junction box was missing a 3/4" knockout. Employees were exposed to a shock hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 F02
- Issued
- Sep 12, 2014
- Abate by
- Oct 16, 2014
- Penalty
- Initial $1,785 · Current $1,250 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: In the SW corner of the weld shop three electrical panels did not have the enclosed breakers clearly marked to indicate the specific purpose of each breaker. Employees were exposed to the electrical shock hazards and/or struck-by hazards.
Recent events (2)
- — I (S) $1249.5
- — Z (S) $1785
1910.303 F03
- Issued
- Sep 12, 2014
- Abate by
- Oct 16, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(3): The markings required by paragraphs (f)(1) and (f)(2) of 29 CFR 1910.303 were not sufficiently durable to withstand the environment involved: In the SW corner of the weld shop three electrical panels had some labels done with chalk and other non-durable markings. Employees were exposed to the electrical shock hazards and/or struck-by hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Primus Sterilizer Company INC
View Primus Sterilizer Company INC's full OSHA safety record →
More inspections in this industry (NAICS 339113)
More inspections in KS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339932899.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.