Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ADVANCED POLY PACKAGING INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ADVANCED POLY PACKAGING INC in 1331 EMMITT DRIVE, AKRON, OH 44306 (NAICS 326111). OSHA activity number 339981532.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Advanced Poly Packaging INC — free Get an email when a new federal OSHA severe-injury report for Advanced Poly Packaging INC is published. One employer, no account, unsubscribe in one click.
Site address
1331 EMMITT DRIVE
City
AKRON
State
OH
ZIP
44306
Mailing
1331 EMMITT DRIVE, AKRON, OH 44306
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326111
Employees
140
Ownership type
A

3 citations on file for this inspection.

1910.106 D04 I

Deleted Serious Gravity 5 1 instance 140 exposed
Issued
Oct 30, 2014
Abate by
Feb 2, 2015
Penalty
Initial $3,960 · Current $0 Reduced
29 CFR 1910.106(d)(4)(i):  Inside storage rooms were not constructed to meet the required test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969.  Openings to other rooms or buildings were not provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height:    Drums of the flammable solvent n-Propanol were stored near the press line.  A fire rated wall and door was not installed to separate the area from the production department and no sills or ramps to contain spills were installed.    In the Alternative:    29 CFR 1910.106(e)(2)(ii)(b)(2):  More than 120 gallons of Category 2, 3, or 4 flammable liquids in containers were located outside of inside storage room(s) or storage cabinet(s) or in any one fire area:    At least 800 gallons of the Category 3 flammable solvent, n-Propanol, was stored in drums near the press line.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3960

1910.305 B01 II

Other-than-serious 1 instance 2 exposed
Issued
Oct 30, 2014
Penalty
Initial $3,366 · Current $0 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:     Panels on the Corona Treater cabinet were not in place, subjecting employees to a possible shock hazard.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3366

1910.219 F03

Other-than-serious 1 instance 2 exposed
Issued
Oct 30, 2014
Penalty
Initial $2,970 · Current $0 Reduced
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed:      The rotator chain was not guarded at the base of the number two extruder.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2970

View Advanced Poly Packaging INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339981532.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.