Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: IEI GENERAL CONTRACTORS, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of IEI GENERAL CONTRACTORS, INC. in 2740 W. MASON ST., GREEN BAY, WI 54307 (NAICS 236210). OSHA activity number 340004332.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch IEI General Contractors, INC. — free Get an email when a new federal OSHA severe-injury report for IEI General Contractors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2740 W. MASON ST.
City
GREEN BAY
State
WI
ZIP
54307
Mailing
1725 MIDWAY RD., DE PERE, WI 54115
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236210
Employees
40
Ownership type
A

2 citations on file for this inspection.

1926.651 J02

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 2, 2014
Penalty
Initial $4,900 · Current $4,900
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary:    (a)  On October 14, 2014 at the NWTC jobsite, the employer failed to ensure excavated material was placed at least two feet from the edge of the excavation. Employee(s) laid new storm sewer pipe and set a manhole in a trench were potentially exposed to fallen soil.
Recent events (3)
  • — F (S) $4900
  • — C (S) $4900
  • — Z (S) $4900

1926.652 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 2, 2014
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) or (c):     (a)  On October 14, 2014 at the NWTC jobsite, the employer did not ensure an employee was adequately protected from cave-ins while installing storm sewer manhole and pipe in an 5'- 6" feet and greater deep trench.