BYRON, GA ·
OSHA Inspection: SOUTHERN PERFECTION FABRICATION HOLDINGS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SOUTHERN PERFECTION FABRICATION HOLDINGS, INC. in 232 HWY 49 SOUTH, BYRON, GA 31008 (NAICS 332999). OSHA activity number 340026772.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SOUTHERN PERFECTION FABRICATION HOLDINGS, INC.
- Site address
- 232 HWY 49 SOUTH
- City
- BYRON
- State
- GA
- ZIP
- 31008
- Mailing
- P.O. BOX 628, BYRON, GA 31008
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 80
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.23 C01
- Issued
- Dec 5, 2014
- Abate by
- Jan 2, 2015
- Penalty
- Initial $5,390 · Current $3,234 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard. On or about 10/21/14 located in Building A on top of the oven, the employer failed to ensure that there were no unprotected floor openings; guardrails were missing leaving a 27 inch opening with a 11.6 foot fall hazard from the lower level.
Recent events (2)
- · I (S) $3234
- · Z (S) $5390
1910.179 J02 III
- Issued
- Dec 5, 2014
- Abate by
- Jan 2, 2015
- Penalty
- Initial $4,620 · Current $2,072 Reduced
General-duty citation text
29 CFR 1910.179(j)(2)(iii): Monthly inspections of hooks, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected, were not performed: On or about 10/21/14 located in Building B the 5 Ton overhead traveling crane; the employer failed to document and retain for the following: services, inspections, repairs, corrective actions, items checked, hooks, and name of person conducted the inspection and the date.
Recent events (2)
- · I (S) $2072
- · Z (S) $4620
1910.303 G02 I
- Issued
- Dec 5, 2014
- Abate by
- Jan 2, 2015
- Penalty
- Initial $5,390 · Current $3,234 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): A) On or about 10/21/14 located in building A, the Oven electrical panel board conduit box cover was missing with exposed conductors; the employer failed to replace the cover to guard against accidents from employees hitting the conductors while servicing the heater on top of the oven.
Recent events (2)
- · I (S) $3234
- · Z (S) $5390
1910.303 G02 I
- Issued
- Dec 5, 2014
- Abate by
- Jan 2, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): A) On or about 10/21/14 located in building B, the Large Shear electrical panel box cover was wide open with exposed conductors; the employer failed to close the door cover to guard against accidents from employees hitting the conductors while operating the Shear.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.147 B
- Issued
- Dec 5, 2014
- Abate by
- Jan 2, 2015
- Penalty
- Initial $10,780 · Current $5,390 Reduced
General-duty citation text
29 CFR 1910.147(b): Authorized employee. A person who locks out or tags out machines or equipment in order to perform servicing or maintenance on that machine or equipment. On or about 10/21/14 located in building B, the Do-All-Saw and the Hem saw the employer failed to follow procedures that clearly and specifically outline the scope, purpose, authorization, for locking out. The employer was placing locks on the saws and putting the key in their pocket and letting the employees work on the saws. The employer is not the Authorized employee.
Recent events (2)
- · I (S) $5390
- · Z (R) $10780
1910.212 A03 II
- Issued
- Dec 5, 2014
- Abate by
- Jan 2, 2015
- Penalty
- Initial $10,780 · Current $5,390 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): A) On or about 10/21/14 located in Building B, the Hem-Saw; the employer failed to ensure that the blade was guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): 9 inch opening not guarded. B) On or about 10/21/14 located in Building B, the Do-All-Saw; the employer failed to ensure that the blade was guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): 13.5 inch opening not guarded.
Recent events (2)
- · I (S) $5390
- · Z (R) $10780
More inspections at Southern Perfection Fabrication Holdings, INC.
View Southern Perfection Fabrication Holdings, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340026772.