PARK HILLS, MO —
OSHA Inspection: LEE MECHANICAL CONTRACTORS, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of LEE MECHANICAL CONTRACTORS, INC. in 508 PARKWAY DRIVE, PARK HILLS, MO 63601 (NAICS 238990). OSHA activity number 340063841.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LEE MECHANICAL CONTRACTORS, INC.
- Site address
- 508 PARKWAY DRIVE
- City
- PARK HILLS
- State
- MO
- ZIP
- 63601
- Mailing
- P.O. BOX 663, PARK HILLS, MO 63601
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 50
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.106 E02 IV D
- Issued
- Nov 14, 2014
- Abate by
- Jan 5, 2015
- Penalty
- Initial $4,000 · Current $4,000
General-duty citation text
29 CFR 1910.106(e)(2)(iv)(d): Flammable liquids were not drawn from or transferred into vessels, containers, or portable tanks within a building only through a closed piping system, from safety cans, by means of a device drawing through the top, or from a container or portable tanks by gravity through an approved self-closing valve: Inside the paint room, employee(s) dispersed flammable AM-75 (acetone, methyl isobutyl ketone) and Trade Group Gun Wash (toluene, xylene and acetone) each from a 55-gallon drum into open metallic buckets without a self-closing valve or equivalent.
Recent events (2)
- — I (O) $4000
- — Z (S) $4000
1910.107 E09
- Issued
- Nov 14, 2014
- Abate by
- Jan 5, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(e)(9): Flammable liquids or liquids with a flash point greater than 199.4 °F (93 °C) were transferred from one container to another,and were not effectively bonded and grounded to prevent discharge sparks of static electricity: Inside the paint room, employee(s) dispersed flammable AM-75 (acetone, methyl isobutyl ketone) and Trade Group Gun Wash (toluene, xylene and acetone) each from a 55-gallon drum into open metallic buckets without grounding and bonding. Grounding and bonding are required to prevent a static spark from igniting the flammable vapors.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.135 A01
- Issued
- Nov 14, 2014
- Abate by
- Jan 5, 2015
- Penalty
- Initial $3,000 · Current $3,000
General-duty citation text
29 CFR 1910.135(a)(1): The employer did not ensure that each affected employee wore a protective helmet when working in areas where there was a potential for injury to the head from falling objects: Inside of the Fabrication shop, employee(s) operating jib and overhead cranes were not wearing protective helmets, hard hats, or the equivalent while suspending and travelling with loads at or above shoulder height.
Recent events (2)
- — I (O) $3000
- — Z (S) $3000
1910.253 B04 III
- Issued
- Nov 14, 2014
- Abate by
- Jan 5, 2015
- Penalty
- Initial $3,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: Alongside the south exterior wall of the Fabrication shop, two partially filled acetylene cylinders were co-stored together with two oxygen cylinders.
Recent events (2)
- — I (S) $0
- — Z (S) $3000
More inspections at LEE Mechanical Contractors, INC.
View LEE Mechanical Contractors, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238990)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340063841.