Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TRU CUT FRAMES, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TRU CUT FRAMES, INC in 89 POSSUM TROT ROAD, PONTOTOC, MS 38863 (NAICS 321912). OSHA activity number 340073022.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch TRU CUT Frames, INC — free Get an email when a new federal OSHA severe-injury report for TRU CUT Frames, INC is published. One employer, no account, unsubscribe in one click.
Establishment
TRU CUT FRAMES, INC
Site address
89 POSSUM TROT ROAD
City
PONTOTOC
State
MS
ZIP
38863
Mailing
89 POSSUM TROT ROAD, PONTOTOC, MS 38863
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321912
Employees
46
Ownership type
A

8 citations on file for this inspection.

1910.22 A02

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 17, 2014
Abate by
Jan 14, 2015
Penalty
Initial $2,100 · Current $1,260 Reduced
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition:    a) Ripsaw #2 - On or about November 4, 2014, the floor between ripsaws had an accumulation of combustible wood scrap and dust that was not maintained as far as possible in a clean condition.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2100

1910.110 D10

Serious Gravity 5 1 instance 46 exposed
Issued
Dec 17, 2014
Abate by
Jan 14, 2015
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.110(d)(10): Precautions were not taken to prevent damage to LP gas system(s) from vehicular traffic:    a) Outside by the office - On or about November 4, 2014, the propane storage tank was not protected from vehicular traffic.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.147 C01

Serious Gravity 5 1 instance 46 exposed
Issued
Dec 17, 2014
Abate by
Feb 5, 2015
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    a) Throughout the facility - On or about November 4, 2014, the employer did not have an energy control program (Lockout/Tagout) for consisting of energy control procedures, employee training, and periodic inspections to prevent the unexpected release of energy for equipment such as but not limited to: ripsaws, vertical band saws, notcher, air compressors, etc.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.213 I01

Serious Gravity 10 2 instances 2 exposed
Issued
Dec 17, 2014
Penalty
Initial $4,900 · Current $2,660 Reduced
29 CFR 1910.213(i)(1): Non-working portion(s) of the blade of bandsaw(s) were not enclosed or guarded:    a) Hardwood department - On or about November 4, 2014, two vertical band saw blade guards were set at 5 inches while employees were cutting wood that was 1.5 inches thick.
Recent events (2)
  • — I (S) $2660
  • — Z (S) $4900

1910.303 G02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 17, 2014
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets of other forms of approved enclosures, or other means listed under this provision:    a) Single line ripsaw #2 - On or about November 4, 2014, live electrical parts were exposed because an electrical box on the back side of the saw had an expanded metal screen that was bent open.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.1200 E01

Serious Gravity 1 1 instance 46 exposed
Issued
Dec 17, 2014
Abate by
Feb 5, 2015
Penalty
Initial $2,100 · Current $1,260 Reduced
29 CFR 1910.1200(e)(1): 29 CFR 1910.1200(e)(1):  The employer did not develop, implement, and maintain at the workplace a written hazard communication program which describes how the criteria specified in paragraphs (f), (g), & (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes items (i) and (ii) of this subparagraph:    a) Throughout the facility - On or about November 4, 2014, the employer had not developed and implemented a written hazard communication which describes the use of labels, safety data sheets (material safety data sheets), and employee training and other subparagraphs.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2100

1904.1 A02

Other-than-serious 1 instance 46 exposed
Issued
Dec 17, 2014
Abate by
Jan 14, 2015
Penalty
Initial $700 · Current $700
29 CFR 1904.1(a)(2): The company has more than ten (10) employees at any time during the last calendar year and did not keep OSHA injury and illness records.  a) Throughout the facility - On or about November 4, 2014, the employer had 46 employees and did not maintain any OSHA injury and illness records.
Recent events (2)
  • — I (O) $700
  • — Z (O) $700

1910.37 B02

Other-than-serious 1 instance 10 exposed
Issued
Dec 17, 2014
Abate by
Dec 30, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  a) Shipping for plywood and hardwood - On or about November 4, 2014, the exit door was not marked by a sign reading "Exit".
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View TRU CUT Frames, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340073022.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.