PONTOTOC, MS —
OSHA Inspection: TRU CUT FRAMES, INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TRU CUT FRAMES, INC in 89 POSSUM TROT ROAD, PONTOTOC, MS 38863 (NAICS 321912). OSHA activity number 343544318.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TRU CUT FRAMES, INC
- Site address
- 89 POSSUM TROT ROAD
- City
- PONTOTOC
- State
- MS
- ZIP
- 38863
- Mailing
- 89 POSSUM TROT ROAD, PONTOTOC, MS 38863
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321912
- Employees
- 60
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C06 I
- Issued
- Nov 28, 2018
- Abate by
- Dec 20, 2018
- Penalty
- Initial $9,054 · Current $5,004 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) Gang Rip Saw - On or about October 17, 2018 the employer had not conducted the periodic inspection of their hazardous energy control procedures.
Recent events (2)
- — I (S) $5004
- — Z (S) $9054
1910.147 C07 I
- Issued
- Nov 28, 2018
- Abate by
- Dec 20, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees. (a) Throughout the production area - On or about October 17, 2018 the employer had not provided adequate training to the employees on the hazardous energy control program at the facility.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D04 I
- Issued
- Nov 28, 2018
- Abate by
- Dec 20, 2018
- Penalty
- Initial $9,054 · Current $5,004 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees. (a) Gang Rip Saw - On or about October 17, 2018 a lockout device was not affixed to the energy isolating device which would prevent exposure to hazardous energy sources.
Recent events (2)
- — I (S) $5004
- — Z (S) $9054
1910.147 D06
- Issued
- Nov 28, 2018
- Abate by
- Dec 20, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(6): Prior to starting work on machines or equipment that have been locked out or tagged out, the authorized employee shall verify that isolation and deenergization of the machine or equipment have been accomplished. (a) Gang Rip Saw - On or about October 17, 2018 authorized employee did not verify the gang rip saw had been isolated and deenergized prior to starting work.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at TRU CUT Frames, INC
View TRU CUT Frames, INC's full OSHA safety record →
More inspections in this industry (NAICS 321912)
More inspections in MS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343544318.