Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EUREKA RESOURCES LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of EUREKA RESOURCES LLC in 34640 RTE 6, WYSOX, PA 18854 (NAICS 562211). OSHA activity number 340083534.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Eureka Resources LLC — free Get an email when a new federal OSHA severe-injury report for Eureka Resources LLC is published. One employer, no account, unsubscribe in one click.
Site address
34640 RTE 6
City
WYSOX
State
PA
ZIP
18854
Mailing
419 SECOND STREET, WILLIAMSPORT, PA 17701
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562211
Employees
19
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 2 instances 19 exposed
Issued
May 7, 2015
Abate by
Jun 11, 2015
Penalty
Initial $7,000 · Current $6,000 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, including blunt force trauma, in that employees were exposed to being struck-by a radial fan impeller blade:    b) Crystallizer Building, Blower Room: On 11/28/2014 at 04:30 PM, a catastrophic failure of blower B20 caused its 4'10" stainless steel impeller to break through its housing and parts of the impeller broke through the building's roof and a wall.  Prior to the failure of blower B20, the stainless steel impellers on the other two radial fans in the series, B21 and B22, developed fractures, were taken out of service, and replaced with high-strength carbon steel impellers.  The employer continued to run the blower B20, ramped the blower up to 99% of its maximum speed of 3300 RPM, and did not inspect the B20 impeller for weaknesses and fractures, via appropriate qualitative and quantitative analysis, to ensure safe operation of the radial fan, discovered on or about 12/02/2014.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $6000
  • — Z (S) $7000

View Eureka Resources LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340083534.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.