NEW YORK, NY —
OSHA Inspection: UPGRADE SERVICES, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of UPGRADE SERVICES, LLC in 1 WORLD TRADE CENTER, NEW YORK, NY 10007 (NAICS 561720). OSHA activity number 340084649.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UPGRADE SERVICES, LLC
- Site address
- 1 WORLD TRADE CENTER
- City
- NEW YORK
- State
- NY
- ZIP
- 10007
- Mailing
- 51 W. 19TH ST, NEW YORK, NY 10011
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561720
- Employees
- 6
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.66 E02 III A
- Issued
- May 11, 2015
- Abate by
- May 21, 2015
- Penalty
- Initial $4,900 · Current $0 Reduced
General-duty citation text
29 CFR 1910.66(e)(2)(iii)(A): Intermittent stabilization system. The system did not keep the equipment in continuous contact with the building facade, and did not prevent sudden horizontal movement of the platform. The system may be used together with continuous positive building guide systems using tie-in guides on the same building, provided the requirements for each system are met. Location: Freedom Tower, New York, NY. a) The scaffold hoist system did not prevent sudden horizontal movement of the platform. The upward movement on the inboard side of the platform continued when all current, by design (i.e., emergency stops were applied); did not stop electrical current to the hoisting system. Two window washers were trapped in the rig as a result of the system's malfunction; on or about 11/12/14.
Recent events (3)
- — F (S) $0
- — C (S) $4900
- — Z (S) $4900
1910.66 E11 VI
- Issued
- May 11, 2015
- Abate by
- May 21, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.66(e)(11)(vi): An effective two-way voice communication system was not provided between the equipment operators and persons stationed within the building being serviced. The communications facility was not operable and was not manned at all times by persons stationed within the building when the platform was being used. Location: Freedom Tower, New York, NY. a) The workers on the platform of unit 1 were not provided with an effective and/or continuous communication. When their rig/unit malfunctioned, the operators utilized one of the 2 radios provided by the employer for communication with the person(s) stationed on the building's rooftop but there was no immediate response; on or about 11/12/14.
Recent events (3)
- — F (O) $2800
- — C (S) $2800
- — Z (S) $2800
1910.66 F04 IX
- Issued
- May 11, 2015
- Abate by
- May 21, 2015
- Penalty
- Initial $4,900 · Current $0 Reduced
General-duty citation text
29 CFR 1910.66(f)(4)(ix): The hoisting machine's primary brake and secondary brake must be in working order and capable of stopping and holding not less than 125 percent of the lifting capacity of the hoist. Location: Freedom Tower, New York, NY. a) The scaffolding hoist system's primary and secondary brakes did not engage when the control button was released, the tilt device was activated (when platform tilted over 10 degrees) and when the 3 emergency stops of unit 1 were applied as it became un-level; on or about 11/12/14.
Recent events (3)
- — F (S) $0
- — C (S) $4900
- — Z (S) $4900
1910.66 F05 II I
- Issued
- May 11, 2015
- Abate by
- May 21, 2015
- Penalty
- Initial $4,900 · Current $0 Reduced
General-duty citation text
29 CFR 1910.66(f)(5)(ii)(I) Portable fire extinguishers conforming to the provisions of 1910.155 and 1910.157 of this part were not provided and securely mounted on all working platforms. Location: Freedom Tower, New York, NY. a) The fire extinguisher provided for the scaffolding hoist system's platform (unit 1) was not mounted properly. When the scaffolding unit sloped, the bracket did not prevent the fire extinguisher from becoming loose; on or about 11/12/14.
Recent events (3)
- — F (S) $0
- — C (S) $4900
- — Z (S) $4900
1910.66 G03 II
- Issued
- May 11, 2015
- Penalty
- Initial $2,100 · Current $2,100
General-duty citation text
29 CFR 1910.66(g)(3)(ii): The employer did not keep a certification record of each inspection and test performed under paragraph (g)(3)(i) of this section. The certification record must include the date of the inspection and test, the signature of the person who performed the inspection and/or test, and an identifier for the platform installation which was inspected. The certification and/or inspection record was not readily available for review by the Assistant Secretary of Labor or the Assistant Secretary's representative. Location: Freedom Tower, New York, NY. a) The scaffolding hoist system's daily scaffold reports were not readily available to OSHA as required; on or about 11/12/14.
Recent events (3)
- — F (O) $2100
- — C (S) $2100
- — Z (S) $2100
1910.66 H01
- Issued
- May 11, 2015
- Abate by
- May 21, 2015
- Penalty
- Initial $4,900 · Current $0 Reduced
General-duty citation text
29 CFR 1910.66(h)(1): General maintenance. All parts of the equipment affecting safe operation were not maintained in proper working order so that they may perform the functions for which they were intended. The equipment was not taken out of service when it was not in proper working order. Location: Freedom Tower, New York, NY. On or about 11/12/14. a) During the window washing operations; The employer noted on scaffold daily report dated 8/19/14 the discovery of substantial defects and/or abnormal conditions in one of the scaffolding hoist units. The employer failed to maintain the scaffold equipment in working order; on or about 11/12/14.
Recent events (3)
- — F (S) $0
- — C (S) $4900
- — Z (S) $4900
1910.66 I01 II C
- Issued
- May 11, 2015
- Abate by
- May 29, 2015
- Penalty
- Initial $3,500 · Current $3,500
General-duty citation text
29 CFR 1910.66(i)(1)(ii)(C): The employees that operate the working platforms were not trained in the emergency action plan procedures required in paragraph (e)(9) of this section. Location: Freedom Tower, New York, NY. a) Employees were not trained in the emergency action plan procedures set by the employer; on or about 11/12/14.
Recent events (3)
- — F (S) $3500
- — C (S) $3500
- — Z (S) $3500
1910.157 G01
- Issued
- May 11, 2015
- Abate by
- May 29, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting. Location: Freedom Tower, New York, NY. a) In case of an emergency employees are expected to use the fire extinguishers which are provided on the scaffolding hoist system's platforms but the employer did not provide training; on or about 11/12/14.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections at Upgrade Services, LLC
View Upgrade Services, LLC's full OSHA safety record →
More inspections in this industry (NAICS 561720)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340084649.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.