Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ION LABS INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ION LABS INC. in 5355 115TH AVE, CLEARWATER, FL 33760 (NAICS 325411). OSHA activity number 340084813.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ION Labs INC. — free Get an email when a new federal OSHA severe-injury report for ION Labs INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ION LABS INC.
Site address
5355 115TH AVE
City
CLEARWATER
State
FL
ZIP
33760
Mailing
5355 115TH AVE, CLEARWATER, FL 33760
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325411
Employees
92
Ownership type
A

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 10 3 instances 6 exposed
Issued
Mar 6, 2015
Abate by
Apr 17, 2015
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) In the blending rooms- employees were exposed to struck by hazards when working around the O'Hara V-Shell Tumble Blenders without guards preventing workers from entering the rotating parts of the blenders. This violation was observed on or about November 17, 2014.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

1910.157 C01

Other-than-serious 1 instance 10 exposed
Issued
Mar 6, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  a) In the hallway on the way to the blending rooms, employees were exposed to fire hazards when a fire extinguisher was missing from where signs or placards claimed that it should be located. This violation was observed on or about November 17, 2014.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View ION Labs INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340084813.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.