Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ION LABS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ION LABS, INC. in 8031 114TH AVE. SUITE 4000, LARGO, FL 33770 (NAICS 325412). OSHA activity number 344630637.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ION Labs, INC. — free Get an email when a new federal OSHA severe-injury report for ION Labs, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ION LABS, INC.
Site address
8031 114TH AVE. SUITE 4000
City
LARGO
State
FL
ZIP
33770
Mailing
8031 114TH AVE. SUITE 4000, LARGO, FL 33770
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325412
Employees
345
Ownership type
A

3 citations on file for this inspection.

1910.134 E01

Serious Gravity 1 1 instance 9 exposed
Issued
Apr 28, 2020
Abate by
May 22, 2020
Penalty
Initial $5,783 · Current $3,470 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  (a) At the workplace: On or about February 10, 2020, employees who were required to wear respirators in the blending rooms during production and cleaning were not provided with a medical evaluation.
Recent events (2)
  • — I (S) $3469.8
  • — Z (S) $5783

1910.305 J02 V

Serious Gravity 1 1 instance 9 exposed
Issued
Apr 28, 2020
Penalty
Initial $5,783 · Current $3,470 Reduced
29 CFR 1910.305(j)(2)(v): A receptacle installed outdoors in a location protected from the weather or in other damp locations did not have an enclosure for the receptacle that was weatherproof when the receptacle was covered (attachment plug cap not inserted and receptacle covers closed):  (a) Blending Room 6 (WB6): On or about February 21, 2020, standard wall receptacle outlets were not covered where a wet process was used to clean the blender, exposing employees to an electric shock hazard.
Recent events (2)
  • — I (S) $3469.8
  • — Z (S) $5783

1904.32 A04

Other-than-serious 1 instance 345 exposed
Issued
Apr 28, 2020
Penalty
Initial $1,928 · Current $1,157 Reduced
29 CFR 1904.32(a)(4): The employer did not post an OSHA 300A Form or equivalent by February 1 thru April 30:  (a) On or about February 10, 2020, the employer failed to post the 2019 OSHA 300A Annual Summary or equivalent form of work related injuries and illnesses.
Recent events (2)
  • — I (O) $1156.8
  • — Z (O) $1928

View ION Labs, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344630637.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.