LARGO, FL —
OSHA Inspection: ION LABS, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of ION LABS, INC. in 8031 114TH AVE. SUITE 4000, LARGO, FL 33773 (NAICS 325411). OSHA activity number 343339370.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ION LABS, INC.
- Site address
- 8031 114TH AVE. SUITE 4000
- City
- LARGO
- State
- FL
- ZIP
- 33773
- Mailing
- 8031 114TH AVE. SUITE 4000, LARGO, FL 33773
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325411
- Employees
- 300
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 I
- Issued
- Oct 15, 2018
- Abate by
- Nov 8, 2018
- Penalty
- Initial $7,391 · Current $4,435 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Production Area - Specific procedures were not developed for machines with multiple energy sources, including air and electricity, on or about September 18, 2018.
Recent events (2)
- — I (S) $4434.6
- — Z (S) $7391
1910.147 D04
- Issued
- Oct 15, 2018
- Abate by
- Nov 8, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4): A lockout device was not attached to all power sources: a) Production Area - Air and electric energy sources were not locked out on filler and capper machines prior to cleaning, on or about September 18, 2018.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at ION Labs, INC.
View ION Labs, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325411)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343339370.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.