OSHA Inspection: MERVAL CONSTRUCTION INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MERVAL CONSTRUCTION INC. in 11210 SOUTHWIND LAKE DRIVE, GIBSONTON, FL 33534 (NAICS 238130). OSHA activity number 340109586.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Merval Construction INC. — free Get an email when a new federal OSHA severe-injury report for Merval Construction INC. is published. One employer, no account, unsubscribe in one click.
Site address
11210 SOUTHWIND LAKE DRIVE
City
GIBSONTON
State
FL
ZIP
33534
Mailing
132 MYAKKA DRIVE, VENICE, FL 34293
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
6
Ownership type
A

4 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 2 instances 2 exposed
Issued
Dec 12, 2014
Abate by
Dec 18, 2014
Penalty
Initial $3,080 · Current $3,080
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a) For employees working at 11210 Southwind Lake Drive in Gibsonton, as observed on or about November 24, 2014. Employees were observed installing plywood sheathing on the roof with a 5:12 pitch. The eave to ground height measured approximately 9 feet 11 inches and the employees had no fall protection system in place.   b) For employees working at 11210 Southwind Lake Drive in Gibsonton, as observed on or about November 24, 2014. Employees were observed installing plywood sheathing on the roof with a 5:12 pitch. The employees were stepping across an approximately 8 inch opening on the roof to access the ladder. The eave to ground height measured approximately 9 feet 11 inches.
Recent events (1)
  • — Z (S) $3080

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 12, 2014
Penalty
Initial $2,200 · Current $2,200
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a) For employees working at 11210 Southwind Lake Drive in Gibsonton, as observed on or about November 24, 2014. Employees were observed installing plywood sheathing on the roof with a 5:12 pitch. The employees were accessing the roof with a portable ladder that was not extended a minimum of 3 feet above the upper landing surface. The eave to ground height measured approximately 9 feet 11 inches.
Recent events (1)
  • — Z (S) $2200

1926.1053 B04

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 12, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:  a) For employees working at 11210 Southwind Lake Drive in Gibsonton, as observed on or about November 24, 2014. Employees were observed installing plywood sheathing on the roof with a 5:12 pitch. The employees were using a stepladder that was in the closed position leaning up against the eave to gain access to the upper working surface. Ladder is designed to be used in the open position with the spreader bars locked.
Recent events (1)
  • — Z (S) $0

1926.20 B02

Other-than-serious 1 instance 2 exposed
Issued
Dec 12, 2014
Abate by
Dec 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s):  a) For employees working at 11210 Southwind Lake Drive in Gibsonton, as observed on or about November 24, 2014. Employees were observed using a ground fault circuit interrupter that was defective. Ground fault circuit protector was physically damaged and inoperable and no inspection prior to use was performed.
Recent events (1)
  • — Z (O) $0

View Merval Construction INC.'s full OSHA safety record →