GIBSONTON, FL —
OSHA Inspection: MERVAL CONSTRUCTION INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MERVAL CONSTRUCTION INC. in 11210 SOUTHWIND LAKE DRIVE, GIBSONTON, FL 33534 (NAICS 238130). OSHA activity number 340109586.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MERVAL CONSTRUCTION INC.
- Site address
- 11210 SOUTHWIND LAKE DRIVE
- City
- GIBSONTON
- State
- FL
- ZIP
- 33534
- Mailing
- 132 MYAKKA DRIVE, VENICE, FL 34293
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 6
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.501 B13
- Issued
- Dec 12, 2014
- Abate by
- Dec 18, 2014
- Penalty
- Initial $3,080 · Current $3,080
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) For employees working at 11210 Southwind Lake Drive in Gibsonton, as observed on or about November 24, 2014. Employees were observed installing plywood sheathing on the roof with a 5:12 pitch. The eave to ground height measured approximately 9 feet 11 inches and the employees had no fall protection system in place. b) For employees working at 11210 Southwind Lake Drive in Gibsonton, as observed on or about November 24, 2014. Employees were observed installing plywood sheathing on the roof with a 5:12 pitch. The employees were stepping across an approximately 8 inch opening on the roof to access the ladder. The eave to ground height measured approximately 9 feet 11 inches.
Recent events (1)
- — Z (S) $3080
1926.1053 B01
- Issued
- Dec 12, 2014
- Penalty
- Initial $2,200 · Current $2,200
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) For employees working at 11210 Southwind Lake Drive in Gibsonton, as observed on or about November 24, 2014. Employees were observed installing plywood sheathing on the roof with a 5:12 pitch. The employees were accessing the roof with a portable ladder that was not extended a minimum of 3 feet above the upper landing surface. The eave to ground height measured approximately 9 feet 11 inches.
Recent events (1)
- — Z (S) $2200
1926.1053 B04
- Issued
- Dec 12, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) For employees working at 11210 Southwind Lake Drive in Gibsonton, as observed on or about November 24, 2014. Employees were observed installing plywood sheathing on the roof with a 5:12 pitch. The employees were using a stepladder that was in the closed position leaning up against the eave to gain access to the upper working surface. Ladder is designed to be used in the open position with the spreader bars locked.
Recent events (1)
- — Z (S) $0
1926.20 B02
- Issued
- Dec 12, 2014
- Abate by
- Dec 24, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s): a) For employees working at 11210 Southwind Lake Drive in Gibsonton, as observed on or about November 24, 2014. Employees were observed using a ground fault circuit interrupter that was defective. Ground fault circuit protector was physically damaged and inoperable and no inspection prior to use was performed.
Recent events (1)
- — Z (O) $0
More inspections at Merval Construction INC.
View Merval Construction INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340109586.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.